DSC Digital Security Control PC158O Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking DSC Digital Security Control PC158O. DSC Digital Security Control PC158O Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
1.1 Specifications
Control Panel Specifications
Flexible Zone Configuration:
Six fully programmable zones
Seven Access Codes: five User, one Master and a
second Master code
Normally Closed, Single EOL, Double EOL
21 Zone Types, 6 Programmable Zone Options
Audible Alarm Output:
Supervised Bell Output (current limited at 3 amps), 12 V
DC
Steady or Pulsed Output
EEPROM Memory: Does not lose programming or
system status on complete AC and Battery failure
Programmable Outputs:
Two Programmable Voltage Outputs, 22
programmable options
- One High Current (300 mA) PGM output on main
panel
- One Low Current (50 mA) PGM output on main
panel
Powerful 1 Amp Regulated Power Supply:
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC Power, Low Battery
Internal Clock Locked to AC Power Frequency
Power Requirements:
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed
lead acid
Remote Keypad Specifications:
Three Different Keypads Available:
- PC5506 6 Zone LED Keypad
- LCD5500 Alphanumeric Keypad
- PC1575RK 6 Zone LED Keypad
The PC5506 and LCD5500 keypads have 5 Fully
Programmable Function Keys
Connect up to 8 Keypads
Four Wire (Quad) Connection to KEYBUS
Built in Piezoelectric Buzzer
System Introduction
SECTION1
Digital Communicator Specifications:
Supports Major Formats including SIA and Contact ID
Event Initiated Personal Paging
Three Programmable Phone Numbers
Two Account numbers
Supports LINKS 1000 Cellular Communication
DTMF and Pulse Dialing
DPDT Line Seizure
Anti-jam Feature
Split Reporting of Selected Transmissions to Each
Telephone Number
System Supervision Features
The PC1580 continuously monitors a number of possible
trouble conditions including:
AC Power Failure
Trouble by Zone
Tamper by Zone
Fire Trouble
Telephone Line Trouble
Failure to Communicate
Low Battery Condition
Bell Output Trouble
Module Fault (Supervisory or Tamper)
Loss of Internal Clock
AUX Power Supply Fault
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Communication Delay
Urgency on Entry Delay
Quick Exit
Additional Features
Auto Arm at Specified Time
Keypad Activated Alarm Output and Communicator
Test
All modules connect to the system via a four wire
KEYBUS up to 1000' (305 m) from main panel
Event Buffer can be printed using PC5400 RS232 Serial
Interface module
Supports the ESCORT 5580 Voice Prompt Module with
Automation/Lighting Control
An Event Buffer which records the past 100 events with
both the time and date at which they occured
Uploading and Downloading capability
• Local Downloading capability with the use of the
PC-LINK Adaptor
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1 - System Introduction

11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• Six fully programmable zones• Seven Access Codes: five User, one Master a

Strona 2 - 1.3 Out of the Box

KEYPADV COMMANDS10• [3] – Auto-Arm TimeThe system can be programmed to Auto-Arm at acertain time. When programming the auto-arming time,enter the time

Strona 3 - Getting Started

KEYPADV COMMANDS11described below. A function is activated by pressing andholding the appropriate key for two seconds.“Stay” – Stay ArmPressing this k

Strona 4 - 2.5 Keypad Assignment

12How to ProgramSECTION4The following section of the manual describes the Installer’sProgramming function and how to program the various sections.You

Strona 5 - 2.8 Zone Wiring

13HOWV TOV PROGRAMlight will turn OFF and the Armed light will turn ON.Refer to Section 5 in this manual to determine what eachoption represents and w

Strona 6 - G E T T I N G S T A R T E D

14Program DescriptionsThe following section explains the operation of all programmablefeatures and options and provides a summary of all corresponding

Strona 7 - Keypad Commands

15P R O G R A M D E S C R I P T I O N S[09] 24 Hour Supervisory Zone (with LINKS)If this zone is violated when the system is either armed ordisarmed,

Strona 8 - [2] Trouble Display

16P R O G R A M D E S C R I P T I O N S5.5 Communicator – Account NumbersThe account number is used by the central station todistinguish between pane

Strona 9

17P R O G R A M D E S C R I P T I O N SOpening (Disarming) Reporting Codes ... Section [42]Opening After Alarm Keypad RingbackSection [6

Strona 10 - KEYPADV COMMANDS

18P R O G R A M D E S C R I P T I O N SAfter a Delinquency Code has been transmitted, itwill not send again until the system has been armedand disarm

Strona 11

19P R O G R A M D E S C R I P T I O N Skey (Hex [C]).The panel has no way of confirming if the pager was calledsuccessfully; a Failure To Communicate

Strona 12 - How to Program

SYSTEMV INTRODUCTION2The LINKS 1000 is only supported by the NorthAmerican AMPS Network and is not supported bythe European GSM Network.1.2 Additional

Strona 13 - 4.5 Viewing Programming

20P R O G R A M D E S C R I P T I O N SThe PGM will activate when any of the following eventsoccur and will remain active for as long as the keypadbu

Strona 14 - Program Descriptions

21P R O G R A M D E S C R I P T I O N Salarm in any way and the Bell will remain silent but the Panicsignal will be sent to the central station. This

Strona 15 - 5.4 Communicator – Dialing

22P R O G R A M D E S C R I P T I O N SThe Fire, Auxiliary, Panic keys will operate even ifKeypad Blanking is active (See Section 5.21 “Key-pad Blank

Strona 16

23P R O G R A M D E S C R I P T I O N SSwinger Shutdown ...Section [62]5.19 Event BufferThe panel will s

Strona 17

24P R O G R A M D E S C R I P T I O N S• if unsuccessful, the panel will try to call using the landlines• if unsuccessful, the panel will try to call

Strona 18 - ✱] key on a touch tone phone

25For the RecordCustomer:_______________________________________________________________________________________Address:______________________________

Strona 19 - 5.9 Downloading

26Keypad Programming[00] Keypad Assignment (Section 2.5 “Keypad Assignment”)Note::::: This must be done at each keypad requiring programming.[0] Slo

Strona 20

27[03] Installer’s Code (Section 4 “How to Program”)Default Default1575 I_______I_______I_______I_______I or 157500 I_______I_______I_______I_______II

Strona 21 - 5.13 Test Transmission

28P R O G R A M M I N G W O R K S H E E T S[10] Third System Option CodeDefault Option ON OFF SectionOFFI________I 1 Arm / Disarm Bell Squawk Enabled

Strona 22

29NOTE::::: For sections [31] to [46], the contents of every section by default is [F].[31] First Telephone Number (32 Digits) (Section 5.6 “Communic

Strona 23 - ✱][8][Installer’s

3Getting StartedSECTION2The following Sections provide a thorough description of how towire and configure devices and zones.2.1 Installation StepsThe

Strona 24 - 5.28 Installer’s Lockout

30[42] [42] [42] [42] [42] Opening (Disarming) Reporting Codes, Access Codes 1-6 (Section 5.7 “Communicator – ReportingCodes”)I_______I_______I Openin

Strona 25 - Programming Worksheets

31[53] Openings & Closings Communicator Call Directions (Section 5.4 “Communicator – Dialing”)Default Option ON OFFONI________I 1 1st Telephone Nu

Strona 26 - Basic System Programming

32[68] LINKS 1000 Preamble (Second Telephone Number) (Section 5.24 “LINKS 1000 Cellular Communicator”)Default: FFFFI_______I_______I_______I_______I (

Strona 27

33[82] Second International Options CodeDefault Option ON OFF SectionOFFI_______I 1 European Dialing Parameters North American Dialing Parameters 5.4O

Strona 28 - Advanced System Programming

Contact IDThe Partition ID Codes must be 4 digits. All reporting codes must be 2 digits.The following is a list of Contact ID reporting codes. The fir

Strona 29 - Communicator Programming

Appendix BSIA FormatLevel 2 (Hardcoded)The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communi

Strona 30

Appendix CAppendix CPROGRAMMINGV LCDV KEYPADSProgramming LCD KeypadsIf you have an LCD5500 Keypad, additional programming is required for proper opera

Strona 31 - (If programmed) 5.6

[62] Third User Display MaskDefault Option ON OFFONI_______I 1 System Test prompt ON System Test prompt OFFONI_______I 2 Time and Date prompt ON Time

Strona 32 - International Programming

38LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the prod

Strona 33 - Special Installer Functions

PC1580 CONTROL PANEL WIRING DIAGRAM✁Control Panel Wiring DiagramTMIncorrect connections mayresult in fuse failure or improperoperation. Inspect wiring

Strona 34 - Appendix A

G E T T I N G S T A R T E D4Programmable Outputs – PGM1 and PGM2Each PGM output is designed sothat when activated by the panel, theterminal will swit

Strona 35 - Appendix B

© 1998 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-9310Printed in Canada

Strona 36 - Appendix C

InstallationManualPC158O• W A R N I N G •This manual contains information on limitations regarding product useand function and information on the limi

Strona 37

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use th

Strona 38 - WARNING Please Read Carefully

Table of ContentsSection 1 – System Introduction 11.1 Specifications... 11.2 Additional

Strona 39 - Control Panel Wiring Diagram

TABLE OF CONTENTSTABLEV OFV CONTENTS5.15 Arming / Disarming Options... 225.16 Entry / Exit Delay Options ...

Strona 40

G E T T I N G S T A R T E D5which slots are occupied in order to generate a fault whena supervisory is not present.How to Assign KeypadsEach keypad m

Strona 41 - Installation

G E T T I N G S T A R T E D62.8.4 Fire Zone Wiring — Four-Wire Smoke DetectorsAll fire zones must be wired according to the followingdiagram:2.8.5 Ke

Strona 42

7Keypad CommandsSECTION3The PC1580 alarm panel can be accessed, controlled andcompletely programmed via any keypad on the system. TheLED keypad uses f

Strona 43 - Table of Contents

KEYPADV COMMANDS8If the Code Required for Bypass option is enabled, onlyuser codes with the Bypass attribute enabled will be able tobypass zones (see

Strona 44 - TABLE OF CONTENTS

KEYPADV COMMANDS9reporting code(s) programmed in section [45] will betransmitted along with the unreported events from anearlier unsuccessful communic

Komentarze do niniejszej Instrukcji

Brak uwag