Przeglądanie stron 46
43
* A/R = alarms/restorals; O/C = openings/closings; O = other
** PPP = partition number; UUU = user number (user 1000=999); ZZZ = zone number
Ref. # Reporting Code Code Sent When...
Dialer
Direction*
Contact
ID
SIA Auto Rep
Codes**
[00040311] Closing 129-1000 user code # 129-1000 used to arm partition O/C (4) A2 CL-UUU
[00040311] Partial Closing one or more zones intentionally bypassed
when partition armed
O/C (4) 56 CW-000
[00040311] Automatic (Scheduled) Clos-
ing
auto arming according to schedule O/C (4) A3 CA-000
[00040311] Auto Arm Cancellation auto arm cancelled O/C (4) A5 CE-000
[00040312] Partition Closing partition armed (partition number indicated) O/C (4) AA CG-PPP
[00040313] Openings partition disarmed (user 001-128 indicated) O/C (4) A2 OP-UUU
[00040314] Opening 129-1000 user code # 129-1000 used to disarm partition O/C (4) A2 OP-UUU
[00040314] Special Opening disarm with WLS909, Second Master code,
keyswitch, downloading or guard code
O/C (4) A2 OP-000
[00040314] Automatic (Scheduled)
Opening
auto disarming according to schedule O/C (4) A2 OA-000
[00040315] Partition Opening partition disarmed (partition number indi-
cated)
O/C (4) AA OG-PPP
[00040316] Battery Trouble/Rest. PC4010 battery is low O (3) A2 YT-000/YR-000
[00040316] AC Line Trouble/Rest. AC power to control panel is disconnected or
interrupted
O (3) AA AT-999/AR-999
[00040316] Panel Bell Trouble/Rest. open circuit detected across bell terminals O (3) 21 YA-999/YH-999
[00040316] Panel Auxiliary Trouble/Rest. aux voltage supply trouble O (3) AA YP-999/YQ-999
[00040316] Combus Trouble/Rest. control panel loses communications with con-
nected module(s) or has low power
O (3) 33 UT-999/UJ-999
[00040316] TLM Failure/Rest. telephone line 1 monitoring trouble (sent via
LINKS. Do not program if LINKS not used)
O (3) 51 LT-001/LR-001
[00040316] TLM Line2 Failure/Rest. telephone line 2 monitoring trouble (sent via
LINKS. Do not program if LINKS not used)
O (3) 52 LT-002/LR-002
[00040316] FTC Restoral control panel has restored communications to
central station (after TLM Fail)
O (3) 54 YK-000
[00040316] Buffer Near Full printer not used or off-line for 450 events O None JL-000
[00040316] User System Test [*][6] bell/communications test O (6) A1 RX-000
[00040316] Periodic Test periodic test transmission O (6) A2 RP-000
[00040316] LINKS Test LINKS test transmission O (6) A3 TX-000
[00040316] Ground Fault/Rest. EGND connection detects a ground fault O (3) 1A US-000/UR-000
[00040316] DLS Lead In DLS Call Back feature only: downloading ses-
sion start
O (4) 11 RB-000
[00040316] DLS Lead Out DLS Call Back feature only:
downloading session complete
O (4) 12 RS-000
[00040316] Installer Lead In Installer code has been entered O (4) 58 LB-000
[00040316] Installer Lead Out Installer's programming complete O (4) 58 LS-000
[00040316] Closing Delinquency programmed number of days for delinquency
has expired without partition being armed
O (4) 54 CD-000
[00040316] Walk Test Enabled walk test mode entered O (6) A7 TS-000
[00040316] Walk Test Disabled walk test complete O (6) A7 TE-000
[00040316] General System Trouble/Rest. indicates one or more of following:
PC4204/PC4820/PC4702 AC, battery and Aux
Supply troubles/rest., PC4400 troubles, auto-
mation fault, PC4164-RS RF jam
O (3) 3A YX-000
[00040316] General Device Low Battery/
Rest.
Wireless zones/pendants (WLS908) 009-128;
handheld keypads (WLS910)
wireless keys (WLS909)
O (3) 84 XT/XR-ZZZ
XT/XR-901-904
XT/XR-921-936
[00040316] Gen Module Comm Fault/
Rest.
control panel loses communications with con-
nected module(s)
O (3) 33 ET-000/ER-000