INSTALLATION
MANUAL
PC1150
This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Reg. No.:
FSCAN-73151-AL-E
REN
=
O.lB
Plug Type
:
RJ31X
MADE IN CANADA
_‘
Przeglądanie stron 0
1 2 3 4 5 6 ... 37 38

Podsumowanie treści

Strona 1 - INSTALLATION

INSTALLATIONMANUALPC1150This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1)this devi

Strona 2 - INSTALLATIONS

To display trouble conditions, enter [*][2]. Trouble conditions are represented with the following lights:LightZone 1Zone 2Zone 3Zone 4“Armed”Low Batt

Strona 3 - TABLE OF CONTENTS

f*]+fsl: User Programming CommandThe [*][5] programming command allows the user to program Access Codes. The first Access Code is theMaster Code and t

Strona 4 - FOR THE RECORD

Setting the Clock[*]+[G]i[Mas terCode]+[ I]The System Clock uses a 24-hour clock format. For example, 8:05 AM would be entered as 0805; 1:30 PM would

Strona 5 - INTRODUCTION

Utility Output Command[*I+[71 or [*]+p]+[Access Code]The Programmable Output (PGM terminal) can be programmed to be activated by a keypad command. Thi

Strona 6

PROGRAMMING GUIDEWith the panel disarmed, enter [*][8][lnstaller’s Code]. The default installer’s Code is 1212. The Installer’sCode should be changed

Strona 7 - Burglary Zone Wiring Chart

Binary Data DisplayZone lights 1 through 4 are used to display the value of each digit of data in a binary format as shown here:ValueZone 1Zone 2Zone

Strona 8 - KEYPAD FUNCTIONS

PROGRAMMING SECTIONS[Of] 1st Phone NumberThis is the first telephone number the Communicator will dial; refer to Section [25] Communicator Call Direct

Strona 9 - [*]+[l]:

3/f format - Non-extencfed reportingRequires:l 3-digit account code in sections [02] or 1041. For example, enter 1230 for account code 123l Format Cod

Strona 10 - Downloading Call-up Command

[OS]Opening [Disamingj Reporting Codes /After Alarm Reporting CodeOpening Reporting Codes are transmitted to indicate disarming of the system by Acces

Strona 11 - Programming

Zone Definitions Digit 2Digit 2 determines the zone type as described below:PIPIPI131r41PIPIPIStandard Delay: Entry and Exit Delays are normally used

Strona 12

NOTES FOR UL INSTALLATIONSThis equipment is UL listed in accordance with UL 1023 (Household Burglar Alarm System Units). Thisequipment has not been in

Strona 13

[12] 1st System Option CodeWhen Section [12] is entered, the 4 Zone Lights, “Ready” and “Armed” lights will indicate which options areenabled. If a li

Strona 14 - PROGRAMMING GUIDE

1143 3rd System Option CodeRefer to Section [12] for programming information.LIGHT111ON =Access code required for bypassl OFF =Access code not require

Strona 15 - HEX Data Programming

El161“Slow” Zone Response Time (01 to 99 x IO ms) Location [5] determines the “slow” zone response time;this time is programmable from 10 ms to 990 ms

Strona 16 - PROGRAMMING SECTIONS

1231 Communication FormatsThis section determines the communication format to be used when transmitting information to the twotelephone numbers progra

Strona 17

Radionics FormatFor conventional Radionics 3/l format, the communications mode should be set on either Radionics rounds [B]or Radionics parity [Cl. Th

Strona 18

PIStrobe Output (Latched Alarm Output)WIThe PGM switches to ground on an alarm and remains low until the panel is disarmed. It can be usedto indicate

Strona 19 - Interior

[30] Reset to Factory DefaultSoftware ResetEntering Section [30] will reset the control panel’s programming to the default settings. When Section [30]

Strona 20

1321 5th System Option CodeRefer to Section [12] for programming instructions.LIGHT[IION =. OFF =PION =. OFF =[31ON =. OFF =[41ON =l OFF =[RION =l OFF

Strona 21

PROGRAMMING WORKSHEETSNOTE: In sections [Ol] to [lo], do not enter data into sections that are not used.1st Phone NumberPage i4Enter [0] for the digit

Strona 22

Closing (Arming) Reporting Codes /Partial Closing Reporting CodePage f5IAccessCode1-AccessCode2-AccessCode3IAccessCode4l---L--AccessCode5/AccessCode6-

Strona 23 - [0] Silent Knight

TABLE OF CONTENTSINTRODUCTIONFeatures...

Strona 24

Maintenance Alarms & RestoralsPage 16DefaultL!3JL_.-.lA3.AJu-l,F,8,,,E,3,-Azz.A_l-l.!z.d%-LEJ.J-Zone DefinitionsLow Battery AlarmAC Fail AlarmFuse

Strona 25

2nd System Option Code Page 18Default Zone Light ON,oFF, -Zone Light 1Zone 4 N.O. without EOL,oFF, -Zone Light 2Master Code not changeable,oFF, -Zone

Strona 26

System Times Page 79Defaultl.lL.!L-Entry Delay (seconds)t?!i_zJ-Exit Delay (seconds),0,4-Siren Cut-off (minutes)J.J_r&u/AC fail transmission delay

Strona 27

[23] Communication Formats Page 21Default&L l--J1st Telephone NumberL.BJ I2nd Telephone NumberA format for both numbers must be programmed, even i

Strona 28 - PROGRAMMING WORKSHEETS

Communicator Call Direction Options Page 23This section must be completely programmed; do not press [#] to exit until all entries are completed.Defaul

Strona 29

4th System Option CodeDefault,ON, /Zone Light 1Page 24Zone Light ONEnable download answer,oFF, IZone Light 2 Enable download callbackDisable callback,

Strona 31

LIMITED WARRANTYDigital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the productshall be free of defe

Strona 32 - Times Page 79

FCC COMPLIANCE STATEMENTThis equipment generates and uses radio frequency energy, and if not installed and used properly, in strict accordance withthe

Strona 33

PROGRAMMlNG SECTlONS[01]1st PhoneNumber...

Strona 34

INTRODUCTIONFEATURESKeypad ProgrammableThe PC1 150 comes complete with a default programso that it is operational straight from the box with aminimum

Strona 35

INSTALLATIONMounting the Pane/The keypad should be located close to the designated “Entry-Exit” door and be mounted at a height convenientfor all user

Strona 36

Burglary Zone WiringBurglary zone definition, (for example, Delay, Instant, 24-Hour, and so on) is programmed using the keypad.Refer to Programming Gu

Strona 37 - LIMITED WARRANTY

KEYPAD FUNCTIONSIntroductionThe PC1 150 keypad provides complete control of the PC1 150 control panel. The panel can be completelyprogrammed from the

Strona 38 - FCC COMPLIANCE STATEMENT

Arming Without Entry DelayTo eliminate the Entry Delay, arm the system by entering [*][9][any Access Code]. An exit through a DelayZone may be made as

Komentarze do niniejszej Instrukcji

Brak uwag