Master Code
The 4 digit Master Code is used to arm and disarm the security system, to
program additional security codes and to change other system features.
The Master Code will be supplied to you by your installer. All keypad
entries are made by pressing one key at a time. (See Additional Codes
section)
Arming the System
Check the following items before arming the system:
Bypass Light
If the “Bypass” light is ON, insure that zones are intentionally bypassed
before arming the system (See Zone Bypassing section).
Trouble Light
If the “ Trouble” light is ON, check to see what the trouble condition is and
call for service. (See Viewing Trouble Conditions section).
Ready Light
If the “Ready” light is NOT ON, check to see that all doors and windows are
closed and that motion is stopped in areas covered by motion detectors.
The system cannot be armed unless the “Ready” light is ON indicating that
all zones are closed.
NOTE: The system may be armed with a zone bypassed or a trouble
present but your security protection will be reduced.
To Arm
Enter your 4 digit access code. As each digit is entered, the keypad
sounder will beep. If the correct access code is entered, the keypad
sounder will beep quickly and the “Armed” light will come ON.
If the access code was entered incorrectly or the “Ready” light comes ON,
the keypad buzzer will sound steadily for 2 seconds. If this occurs, press
the [#] key and re-enter your access code.
When the correct access code is entered and the “Armed” light comes ON,
exit the premises through the door indicated by your installer as the Exit-
Entry door.
At the end of the exit delay period, all lights, except the “Armed” light, will
go out and the system will be armed. The exit time delay can be changed
by your installer.
Auto-Bypass Option - Home-Away Arming
This feature, if selected by your installer, will allow you to arm your system
with any valid user code and the system will automatically bypass the
interior zones. The “Bypass” light will come on. If you exit within the allowed
exit time, the system will automatically activate the interior zones and the
“Bypass” light will go out. This feature is designed to save the customer
from having to manually bypass interior zones each time they wish to arm
the system and remain at home.
In residential applications where the system has been armed and the
interior zones are automatically bypassed, the interior zones can be
reactivated from a keypad that is outside the interior zone's protection area.
To reactivate the interior zones, press [
*
] then [1] and the “Bypass” light
will go out.
www.ealarm.com.my
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Arming the System

2Master CodeThe 4 digit Master Code is used to arm and disarm the security system, toprogram additional security codes and to change other system feat

Strona 2 - Door Chime Feature

3Entry Delay Off ArmingIf you wish to arm your system and eliminate the entry delay, enter [*][9]before your access code. The “Armed” light will flash

Strona 3 - One-Time Use Code

4Alarm TestEnter [*][6][Master Code][8] for a 2-second test of the keypad lights,keypad buzzer, battery and the bell/siren.Press [#] to return to Read

Strona 4 - Viewing Trouble Conditions

5NOTE: The alarm memory is cleared each time the panel is armed so thatany alarms showing are alarms that occurred only during the lastarmed period.If

Strona 5 - Fire Alarm Operations

6Pressing any key on the keypad will silence the sounder but the “Trouble”light will remain ON until the trouble condition is cleared. If you cannotde

Strona 6 - Maintenance

7ResetTo restore the smoke detector(s) to normal, press [*][7]. If the detector stillhas smoke in it, the alarm will resound and the sequence describ

Strona 7 - INSTALLER

8 9Press [F] for 2 seconds to activateFIRE transmission.Press [A] for 2 seconds to activatean AUXILIARY transmission.Press [P] for 2 seconds to activa