Installation
Manual
W A R N I N G •
This manual contains information on limitations regarding product use
and function and information on the limitations as to liability of the
manufacturer. The entire manual should be carefully read.
PC51O
Software Version 1.O
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Installation

InstallationManual• W A R N I N G •This manual contains information on limitations regarding product useand function and information on the limitation

Strona 2

8Important Note about Keypad [∗∗∗∗∗] CommandsThe [∗] commands will not function when the system is disarmed and the bell or siren is active. In order

Strona 3 - TABLE OF CONTENTS

9PROGRAMMING GUIDEWith the system disarmed, enter [∗][8][Installer’s Code]. The system can only be programmed while it isdisarmed. The default Insta

Strona 4 - INTRODUCTION

10PROGRAMMING SECTIONS[1] Zone DefinitionsEnter four 2-digit numbers in this section to determine the operating characteristics of each zone.Zone Defi

Strona 5 - INSTALLATION

11[2] System TimesThree system times are programmed in Section [2]; each time requires a 3-digit number. Do not press the [#]Key during data entry.[1

Strona 6 - DC. The

12[8] [F], [A] and [P] Key Alarms: The PGM output switches to ground when any of the keypad alarms aregenerated by pressing the [F], [A] or [P] Keys.

Strona 7 - KEYPAD FUNCTIONS

13FOR THE RECORDCustomer ___________________________________________________________________________________Address __________________________________

Strona 8 - To Bypass Zones:

14[1] Zone Definitions Page 10NOTE: When defining zones, assign delay zones first, then assign the other types.Default0 0 Zone 10 1 Zone 20 2 Zone

Strona 9 - Erasing a Code

15HOOK-UP DIAGRAMAUX 1 AMPBELL 5 AMPBATT 5 AMPDO NOT REPLACE FUSESWITH HIGHER VALUESTHAN SHOWNPC510BELL/SIREN1A MAX.OBSERVE POLARITY!BATTERY12V GELL C

Strona 10 - ] Commands

LIMITED WARRANTYDigital Security Controls Ltd.’s liability for failure to repair the prod-uct under this warranty after a reasonable number of attempt

Strona 11 - PROGRAMMING GUIDE

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contactwith system users, it is your

Strona 13 - [3] Installer’s Code

©1997, 2002 Digital Security Controls Ltd.Toronto, CanadaPrinted in Canada 29000864 R11-800-387-3630

Strona 14 - Notes on [P] Key Operation

1TABLE OF CONTENTSINTRODUCTION 2Features ...

Strona 15 - FOR THE RECORD

2INTRODUCTIONFEATURES• Fully featured security system with TroubleSupervision, Alarm Memory, Master Code and 3programmable Access Codes, Quick-Arming

Strona 16 - Do not enter 0

3INSTALLATIONMounting the PanelSelect a dry location close to an unswitched AC source and a ground connection.Remove the printed circuit board, mounti

Strona 17 - HOOK-UP DIAGRAM

4WiringNOTE: Complete all wiring to the control panel before applying battery or AC power.Burglary Zone WiringBurglary zone definition, (for example,

Strona 18 - LIMITED WARRANTY

5KEYPAD FUNCTIONSIntroductionThe Keypad provides complete control of the PC510 security system. The system can be completelyprogrammed from the keypa

Strona 19 - WARNING Please Read Carefully

6DisarmingEnter the premises through the designated Entry-Exit door. The keypad will sound a tone to indicate that thesystem must be disarmed. Go to

Strona 20 - 1-800-387-3630

7[∗]+[5]+[Master Code]: Program Access CodesThe [∗][5][Master Code] command allows the user to program the Master Code and 3 additional AccessCodes.E

Komentarze do niniejszej Instrukcji