DSC Power8 PC5OO5 Instrukcja Instalacji Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
23
Section 9: International Programming
[700] Clock Adjust
Default: 60 I_______I______I Valid entries are 01-99 seconds
[701] First International Options Code
Default Option ON OFF
OFF I_______I 1 50 Hz AC 60 Hz AC
OFF
I_______I 2 Time Base - Internal Crystal Time Base - AC Line
OFF
I_______I 3 AC/DC Arming Inhibit Enabled AC/DC Arming inhibit disabled
OFF
I_______I 4 All System Tampers Require Installer Reset All System Tampers follow Restore
OFF
I_______I 5 6 digit User Access Codes 4 digit User Access Codes
OFF
I_______I 6 Busy Tone detection enabled Busy Tone detection disabled
OFF
I_______I 7 High Current Battery Charge Standard current battery charge
OFF
I_______I 8 For Future Use
[702] Second International Options Code
Default Option ON OFF
OFF
I_______I 1 Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60
ON
I_______I 2 Force Dialing Enabled Force Dialing Disabled
OFF
I_______I 3 Land Line Test Transmission in Minutes Land Line Test Transmission in Days
OFF
I_______I 4 1600 Hz Handshake Standard Handshake
OFF
I_______I 5 ID Tone Enabled ID Tone Disabled
OFF
I_______I 6 2100 Hz ID Tone 1300 Hz ID Tone
OFF
I_______I 7 One Time 1-Hr User Enabled DLS Window Full 6-Hr User Enabled DLS Window
OFF I_______I 8 Bell on FTC when Armed FTC Trouble only when Armed
[703] Delay Between Dialing Attempts
Default:003
I_______I_______I_______I Valid entries are 000-255 Seconds