DSC Power832 PC5015 Instrukcja Instalacji Strona 23

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 36
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 22
21
Clearing Troubles
[4] Failure to Communicate
Panel unable to send information to
central station. Check telephone
line, telephone number of Central
Station, format and reporting
codes. Dial number from handset
and listen for tones to ensure
number correct.
[5] Zone Fault
The trouble will be indicated if any
zone on the system is in a trouble
condition, i.e. if it could not send
an alarm to the panel if required to
do so. Press [5] to view the zone
number.
[6] Zone Tamper
This condition will only be gener-
ated for zones with DEOL resistor
supervision. This trouble is gener-
ated when a tamper is present.
Press [6] whilst in trouble mode to
view zone with a tamper condition.
[7] Device Low Battery
Generated when a wireless device
exhibits a low battery. Press [7]
again to view which devices have
low battery.
[8] Loss of System Time
This condition occurs when the
control unit is powered up and the
internal clock has not been set up.
[*][6][Master Code][1] to put in new
date and time.
Clearing Troubles
Przeglądanie stron 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 35 36

Komentarze do niniejszej Instrukcji

Brak uwag