Section 2: User Commands
5
Section 2: User Commands
Any system keypad can be used to program or perform any keypad command. LED keypads use status and zone indicator lights to represent
alarm functions and status. The LCD keypad displays the description and status indicator lights represent alarm functions and status. This section
describes basic keypad commands. Refer to the PC1616/1832/1864 Reference Manual for detailed description of all keypad commands.
Press the
[#] key to reset the keypad if an error has been made entering user codes or keypad commands.
Section 2.1 – Away Arming
The Ready light must be ON to arm the system. If the Ready light is OFF, ensure all protected doors and windows are secure or bypassed.
To arm the system in the Away mode, either press and hold the Away function button for 2 seconds or enter a valid user code and leave the
premises through a door programmed as Delay. Upon arming, the Armed light will turn ON. If a user code was used to arm the system and
Stay/Away zones are programmed, the Bypass light will turn ON and will turn OFF when a door programmed as Delay is violated. If the
Audible Exit Delay option is enabled, the keypad will beep once every second during the exit delay (and three times a second during the last
10 seconds) to alert the user to leave.
Section 2.2 – Stay Arming
The Ready light must be ON to arm the system. If the Ready light is OFF ensure all protected doors and windows are secure or bypassed.
To arm the system in the Stay mode, either press and hold the Stay function button for 2 seconds or enter a valid user code and stay within the
premises (do NOT violate a door programmed as Delay). Upon arming, the Armed light and Bypass light will turn ON. If the Stay function
button is used, the keypad will not beep during the exit delay. If a user code was used, the keypad will beep if the Audible Exit Delay option
is enabled.
Section 2.3 – Disarming
The user must enter through a door programmed as Delay. Upon entering, the keypad will emit a steady tone (and emit a pulsing tone during
the last 10 seconds of entry delay) to alert the user to disarm the system. Enter a valid user code to disarm the system. If an alarm occurred
while the panel was armed, the Memory light and the zones that went into alarm will be flashing (LED keypad) or the keypad will display
‘Alarm in Memory’ (LCD keypad). Press the [#] key to return the keypad to the Ready state.
Section 2.4 – [] Commands
The following is a list of the [] commands available and a description of each:
[][1] Bypass (disarmed state)/Reactivate Stay/Away Zones (armed state)
[][2] Display Trouble Conditions
[][3] Display Alarm Memory
[][4] Door Chime Enable/Disable
[][5] User Code Programming
[][6] User Commands
[][7][x] Command Functions 1 – 4
[][8] Installer Programming
[][9][code] No-Entry Arming
[][0] Quick Arm (disarmed state)/Quick Exit (armed state)
[][1] Bypass/Re-activate Stay/Away Zones
LED Keypad:
Press [][1] to enter the bypass mode. If the Code Required for Bypass option is enabled, enter a valid user code. The Bypass light will
flash. The keypad will turn ON the corresponding zone light to indicate a zone is bypassed. To bypass or unbypass a zone, enter the 2-digit
zone number. Once the correct zones are bypassed, press [#] to exit. The Bypass light will be ON if any zones are manually bypassed.
LCD Keypad:
Press [][1] to enter the bypass mode. If the Code Required for Bypass option is enabled, enter a valid user code. The keypad will display
‘Scroll to View Zones’. The keypad will display the programmed zone labels for the zones and include the letter ‘O’ in the bottom, right cor-
ner if the zone is violated or the letter ‘B’ if the zone is bypassed. Scroll to the appropriate zone and press the [] key to change the bypass
status (or enter the 2-digit zone number). Once the correct zones are bypassed, press [#] to exit.
Additional Bypass Commands:
Bypass Recall: Press [99]. The keypad will recall the last group of zones that were bypassed
Clear Bypass: Press [00]. The keypad will clear the bypass on all zones.
Save Bypass: Press [95]. The keypad will save which zones are manually bypassed.
Recall Save: Press [91]. The keypad will recall the bypassed zones that were saved.
Hold Up Zones cannot be assigned to bypass groups.
Re-activate Stay/Away Zones:
Press [][1] when the system is armed in the Stay mode to change the armed status to Away mode. The system will add the Stay/Away
zones back into the system after the exit delay time expires.
Przeglądanie stron 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 63 64

Komentarze do niniejszej Instrukcji

Brak uwag

Mitel M7310N manuals

Owner’s manuals and user’s guides for Telephones Mitel M7310N.
We providing 4 pdf manuals Mitel M7310N for download free by document types: User Manual






More products and manuals for Telephones Mitel

Models Document Type
M3310 User Manual   M3310 - Mitel Edocs, 23 pages
INT1400 User Manual   MITEL 3000 Communications System, 8 pages
M3310 User Manual   M3310 - Mitel Edocs, 23 pages
5235 IP Phone User's Guide   Mitel 5235 IP Phone User guide, 88 pages
M685i Installation Guide   Mitel M685i Installation guide, 16 pages
M685i User Manual    Mitel M685i Expansion Module, 2 pages
Panther II 1032 Service Manual   Mitel Panther II 1032 Service manual, 108 pages
3000 Specifications   Mitel 3000 Specifications, 129 pages
1000 guide Technical Information   Mitel 1000 guide Technical information, 226 pages
3000 User Manual   Mitel 3000 Quick Reference Guide, 13 pages
Panther II 820 Specifications   Mitel Panther II 820 Specifications, 69 pages
4125 User Manual   ACD Agent/Supervisor User Guide - 4025/4125, 41 pages
1000 guide User's Guide   Mitel 1000 guide User guide, 94 pages
Symbol User Manual   Phone Reference Guide, 130 pages
5606 User Manual   Mitel 5340 IP Phone Datasheet, 4 pages
50005070 Instruction Manual   Mitel 50005070 Programming instructions, 416 pages