Installation
Manual
WARNING
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
PC585 software version 3.0
DLS 2002 and hi
g
her
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - Installation

InstallationManualWARNINGThis manual contains information on limitations regarding product use and function and information on the limitations as to l

Strona 2 - WARNING Please Read Carefully

6NOTE: This option can only be selected if Normally Closed (NC) detection devices or contacts are being used. NOTE: Only one NC contact can be conne

Strona 3 - Table of Contents

Getting Started: 2.11 Keypad Zones7Assigning Keypad ZonesWhen using keypad zone inputs, each input used must beassigned a zone number in Installer’s P

Strona 4 - PC585 Wiring Diagram

8Section 3: Keypad CommandsUse any system keypad to enter commands and/or programthe PC585 security system. The LED keypad uses functionand zone indic

Strona 5 - 1.1 Specifications

Keypad Commands: 3.4 [*] Commands9[*][2] Trouble Display The panel constantly monitors itself for several different trou-ble conditions. If a trouble

Strona 6 - 1.3 Out of the Box

10[*][5] Programming Access CodesThere are 37 access codes available to the user. They are:Access code (40) ... One master code Acce

Strona 7 - Section 2: Getting Started

Keypad Commands: 3.5 Function Keys11[*][7] Command Output FunctionsThe user can activate programmable output functions usingthe [*][7][1-2] commands.

Strona 8

123.6 Features Available for the LCD5500Z These features are only available for LCD5500Z keypads withzone inputs:Automatic Scrolling of Alarms in Memo

Strona 9 - 2.8 Zone Wiring

13Section 4: How to ProgramThe following section of the manual describes the Installer’sProgramming function and how to program the various sec-tions.

Strona 10 - 2.11 Keypad Zones

144.4 Programming Toggle Option SectionsSome programming sections contain several toggle options.The panel will use zone lights 1 through 8 to indicat

Strona 11

15Section 5: Program DescriptionsThe following section explains the operation of all programma-ble features and options and provides a summary of all

Strona 12 - Section 3: Keypad Commands

Limited WarrantyDigital Security Controls Ltd. warrants the original purchaser that for a period of twelve months fromthe date of purchase, the produc

Strona 13

16A violated Fire zone will be displayed on all keypads and canbe delayed at any keypad. Typically this zone is used forlatching smoke detectors.[08]

Strona 14

Program Descriptions: 5.4 Assigning Keypad Zones17NOTE: Any zone with the wireless attribute enabled will not cause an alarm for a fault condition wh

Strona 15 - 3.5 Function Keys

18NOTE: To use the Third Telephone Number, you must enable itin section [380], option [5], and program it in section [303].NOTE: Telephone numbers can

Strona 16

Program Descriptions: 5.9 Communicator – Reporting Formats19reporting code to the central station, if programmed. If thereis a closing or zone activi

Strona 17 - Section 4: How to Program

201. If an event’s reporting code is programmed as [00] or [FF],the panel will not attempt to call central station.2. If the reporting code for an eve

Strona 18 - 4.5 Viewing Programming

Program Descriptions: 5.11 PGM Output Options21using the LINKS1000 with call back, you need to program theLINKS1000 Preamble with the downloading tele

Strona 19 - 5.2 Zone Programming

22NOTE: If attribute [8] is turned ON, attributes [1-7] must also be turned ON.PGM Output Timer. . . . . . . . . . . . . . . . . . . . . . . Section [

Strona 20 - 5.3 Zone Attributes

Program Descriptions: 5.13 Bell23TLM Enable/Disable . . . . . . . . . . . . . . . . . . Section [015]: [7] TLM Trouble Beeps When Armed or TLM Audibl

Strona 21 - 5.5 Communicator – Dialing

24squawk the bell only when the system is away armed or dis-armed.The Opening After Alarm Keypad Ringback option willcause the keypad to beep 8 times

Strona 22

Program Descriptions: 5.20 Event Buffer255.20 Event BufferThe panel will store the last 128 events which occurred on thesystem. The Event Buffer will

Strona 23

iTable of ContentsSection 1: System Introduction 11.1 Specifications ...11.2 Add

Strona 24 - 5.10 Downloading

26When used as a backup communicator, the panel will attemptto call the central station in the following manner:the panel will try to call using land

Strona 25 - 5.11 PGM Output Options

27Restore PC5132 to Default Programming . . . . Section [996]Restore PC5400 Printer to Default ProgrammingSection [997]Restore Panel to Default Prog

Strona 26

28Section 6: Programming WorksheetsFor the RecordCustomer: ___________________________________________________________________________________________

Strona 27 - 5.17 Arming/Disarming Options

Programming Worksheets29Zone Programming SummaryZone programming can be found in sections [001] - [004], [101] - [132], [020] and [202] - [205]. Use

Strona 28 - 5.19 Swinger Shutdown

30Keypad Programming[000] Keypad Enrollment (Section 2.5 “Keypad Assignment”)NOTE: This must be done at each keypad requiring programming.[0] Slot

Strona 29

Programming Worksheets31NOTE: Zones 9-32 are only available for wireless zones.[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming”)Default Def

Strona 30 - 5.29 Timebase

32[012] Keypad Lockout Options (Section 5.21 “Keypad Lockout Options”)NOTE: If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch

Strona 31 - 5.33 Daylight Savings Time

Programming Worksheets33[017] Fifth System Option CodeDefault Option ON Off Section ONI________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses A

Strona 32 - For the Record

34Advanced System ProgrammingZone Attributes (Section 5.3 “Zone Attributes”)Zone Attribute Defaults (Y = Option ON; N = Option OFF):Section Zone # Zon

Strona 33 - Zone Programming Summary

Programming Worksheets35[117] 17 ( ) I________I I________| I________| I________| I________| I________| I________| I________I[118] 18 (

Strona 34 - Basic Programming

iiPC585 Wiring Diagram

Strona 35

36[160] Maximum Dialing Attempts to Each Telephone Number (Section 5.5 “Communicator – Dialing”)Default: 008 I_______I_______I_______I Valid entries a

Strona 36

Programming Worksheets37Alarm Restoral Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” & Appendix A)Section[324] Zone 1

Strona 37 - Programming Worksheets

38Closing (Arming) Reporting Codes, Access Codes 1-32 (Section 5.8 “Communicator – Reporting Codes” & Appendix A)Section[339] Code 1 Code 2 Code

Strona 38 - Advanced System Programming

Programming Worksheets39[352] Test Transmission Reporting Codes (Section 5.8 “Communicator – Reporting Codes” & Appendix A)I_______I_______I 1. P

Strona 39 - PGM Option

40[370] Communication VariablesDefault Section003I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled) 5.

Strona 40 - Communicator Programming

Programming Worksheets41Downloading Options[401] First Downloading Option Code (Section 5.10 “Downloading”)Default Option ON OffOFF I_______I 1

Strona 41

42Module Programming[801] PC5400 Printer Module Programming Please refer to your PC5400 Installation Manual for installation and programming instructi

Strona 42

43 Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA for-mat reporting codes. For more information on reporting cod

Strona 43

44Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when usingthe standard (non-

Strona 44

45 Appendix B: Programming KeypadsIf you have an LCD5500Z keypad, additional programming is required for proper operation. All LCD programming is done

Strona 45 - International Programming

1Section 1: System Introduction1.1 SpecificationsDownloading Software Support• PC585 v3.0 uses DLS 2002 and higherFlexible Zone Configuration• Four fu

Strona 46 - Special Installer Functions

46[60] First User Display MaskDefault Option ON OFFONI_______I 1 Hold [P]anic Keys prompt ON Hold [P]anic Keys prompt OFFONI_______I 2 Zone Bypassing

Strona 47 - Appendix A: Reporting Codes

47[66] Keypad OptionsDefault Option ON OFFONI_______I 1 Display Access Code when Programming Display ‘X’ when ProgrammingONI_______I 2 Local Clo

Strona 48 - Restoral

48Programmable Labels Zone labels and other LCD display identifiers can be customized to make operation of the system easier for the end user. The fol

Strona 49

Programming Worksheets: 5.33 Daylight Savings Time49[075] Fourth User Display MaskDefault Option ON OFFONI_______I 1 User Initiated Call-up prompt

Strona 50

50Command Output LabelsDefault: “Command_O/P_1” - “Command_O/P_4”Program a label for each Command Output used, as it will appear at each partition.Sec

Strona 51 - ASCII Characters

Programming Worksheets: 5.33 Daylight Savings Time51[997] View Software Version[998] Initiate Global Label BroadcastAll LCD programming is done per ke

Strona 52

©2002 Digital Security Controls Ltd.Toronto, Canada • www.dsc.comTechnical Support 1-800-387-3630Printed in Canada 29034576 R002Direct all comme

Strona 53

21.2 Additional DevicesIn addition to the information below, see the back cover for aDSC module compatibility table.PC5132 Wireless ReceiverThe PC5132

Strona 54

3Section 2: Getting StartedThe following sections provide a thorough description of howto wire and configure devices and zones.2.1 Installation StepsR

Strona 55

4Programmable Output Terminals – PGM1 and PGM2PGM1 can sink up to 50mA or300mA (depending on the PGMbuild option) of current. Connect thepositive sid

Strona 56 - PC585 Module Compatibility

Getting Started: 2.5 Keypad Assignment52.5 Keypad AssignmentThere are eight available slots for keypads. LED keypads andthe LCD5501Z keypad by default