PowerSeries - PC1616/PC1832/PC1864
28
Programmable Output Options
01 Residential Burglary and Fire Bell Output 15 Remote Operation (DLS-3 Support)
02 For Future Use 16 For Future Use
03 Sensor Reset [*][7][2] 17 Away Armed Status
04 2 Wire Smoke Support (PGM 2 only) 18 Stay Armed Status
05 System Armed Status 19 Command Output #1 ([*][7][1])
06 Ready To Arm 20 Command Output #2 ([*][7][2])
07 Keypad Buzzer Follow Mode 21 Command Output #3 ([*][7][3])
08 Courtesy Pulse 22 Command Output #4 ([*][7][4])
09 System Trouble Output (with Trouble options) 23 24 Hour Silent Input
10 System Event [Strobe (with Event options)] 24 24 Hour Audible Input
11 System Tamper (all sources: zones, keypad, modules) 25 Delayed Fire and Burglary Output
12 TLM and Alarm 29 Zone Follower Output
13 Kissoff Output 30 Partition Status Alarm Memory
14 Ground Start Pulse
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01
I_______I_______I PGM 3 (main panel/PC5208)* 01 I_______I_______I PGM 7 (PC5208)
01 I_______I_______I PGM 4 (main panel/PC5208)* 01 I_______I_______I PGM 8 (PC5208)
01 I_______I_______I PGM 5 (PC5208) 01 I_______I_______I PGM 9 (PC5208)
01 I_______I_______I PGM 6 (PC5208) 01 I_______I_______I PGM 10 (PC5208)
These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the PC5208. If you use
both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output, and PGM4 will work the same as the sec-
ond PC5208 output.
[011] PGM 11 to PGM 14 Output Programming (PC5204)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01
I_______I_______I PGM 11 01 I_______I_______I PGM 13
01 I_______I_______I PGM 12 01 I_______I_______I PGM 14
Other System Options
[012] Keypad Lockout Options
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000 I_______I_______I_______I Lockout Duration (001-255 minutes)
[006] Installer’s Code [007] Master Code [008] Maintenance Code
Default Default Default
5555 I_______I_______I_______I_______I 1234 I_______I_______I_______I_______I AAAA I_______I_______I_______I_______I
[009] PGM1 and PGM2 Output Programming (Main Panel)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
19
I_______I_______I PGM 1 10 I_______I_______I PGM 2
Output types [03] and
[20] cannot be used
together on the same
system.