PC1500 Version 4.1
[34] 6th System Option Code
Page 17
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 Audible Exit Delay with Urgency Standard Exit Delay
OFF Zone Light 2 Bell Squawk during Exit Delay No Bell Squawk during Exit Delay
OFF Zone Light 3 Audible Exit Fault enabled Audible Exit Fault disabled
OFF Zone Light 4 Urgency applied to Entry Delay Standard Entry Delay
OFF Zone Light 5 Bell Squawk during Entry Delay No Bell Squawk during Entry Delay
OFF Zone Light 6 [F] Key disabled [F] Key enabled
[35] LINKS1000 Test Reporting Code
Page 18
Default
FF
Program this section only if the LINKS1000 Cellular Alarm Transmitter
is being used with the PC1500.
[36] Keypad Lockout Control
Page 18
Default
0 0 Number of Invalid Codes before lockout
0 0 Lockout Duration (minutes)
Enter 2 2-digit numbers in the range of 00 to 99. Program the Number of Invalid Codes as 00 to disable the
lockout feature.
[90] Installer’s Lockout Enable
Page 18
[91] Installer’s Lockout Disable
Page 18
WARNING!
Panels returned to DSC with the Installers Lockout enabled and no other apparent problems will be subject to an
additional service charge!