35
[380] - FIRST COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Communications ON Communicator Enabled.
The system’s communicator will be enabled and all events with
reporting codes will be reported to the monitoring station. Refer to the Telephone Number,
reporting code and Call Direction Programming Sections.
OFF Communicator Disabled.
The system’s communicator will be shut off and events will not be
transmitted to the monitoring station. Downloading may still be performed if enabled.
2 Restore Transmission ON Restore Transmissions on Bell Time-out.
Zone restoral reporting codes will not be transmit-
ted until the zone has been restored and the Bell time-out has expired. If the zone is not
restored when the bell time-out expires, the restoral will be transmitted when the zone physi-
cally restores or when the system is disarmed.
NOTE: 24-hr zones will not restore until the zone is physically restored.
OFF Restore Transmissions Follow Zones
. Zone restoral reporting codes will be transmitted when
the zone is physically restored. If the zones are still active when the system is disarmed, the
restore codes will be transmitted when the system is disarmed.
NOTE: 24-hr zones will not restore until the zone is physically restored.
3 Dialing Method ON Pulse Dialing enabled.
The control panel will dial telephone numbers using pulse (rotary) dialing.
OFF DTMF Dialing enabled.
The control panel will dial telephone numbers using DTMF (dual tone
multi-frequency) dialing.
4 Switch to Pulse Dialing ON Switch to Pulse Dialing after 4 DTMF attempts.
If DTMF dialing is enabled, the control panel
will dial telephone numbers using DTMF dialing for the first 4 attempts. If unsuccessful, the con-
trol panel will switch to pulse (rotary) dialing for the remaining attempts.
OFF DTMF Dial for all Attempts.
If DTMF dialing is enabled, the control panel will dial telephone
numbers using DTMF dialing for all dialing attempts.
5 3rd Phone Number Enable ON 3rd Phone Number Enabled
. The 3rd Phone number will be used for Alternate Dialing with
the 1st phone number or as a backup of the 1st phone number (see light 6).
OFF 3rd Phone Number Disabled
. The 3rd Phone number will not be used.
6 3rd Phone Number ON Alternate Dialing Enabled (1st & 3rd).
After each dialing attempt, the communicator
switches between the 1st phone number and 3rd phone number.
OFF Call 1st Number, Backup to 3rd Number.
If the programmed number of attempts to commu-
nicate to the First Telephone Number fail, the same number of attempts will be made to com-
municate to the Third Telephone Number. If all attempts to communicate to the Third Telephone
Number fail, a Failure to Communicate Trouble will be generated.
7 LINKS Dialing ON Call LINKS as well as Land Line(s).
The control panel will dial the programmed number of
attempts through the LINKS, followed by the number of programmed attempts over the land-
line regardless of whether the communication over the LINKS was successful.
OFF LINKS is backup of Land Line(s).
The control panel will dial through the LINKS if the panel is
having difficulty communicating over the phone line. For each failed attempt to the land line,
one attempt will be made to the LINKS1000.
8 Delinquency ON Delinquency Follows Zone Activity (Activity Delinquency).
This feature assists in the mon-
itoring of the elderly and the handicapped. If there is no zone activity on the system, the Delin-
quency Transmission Delay timer in Section [370] will begin counting in hours. When the
counter reaches the programmed time, the panel will communicate the Delinquency Code to
the central station, if programmed. If there is zone activity present on the system at any time,
the counter will be reset. If this option is used, the Closing Delinquency option is not available.
OFF Delinquency Follows Arming (Closing Delinquency).
This reporting code is sent whenever
the programmed number of days for Delinquency has expired without the system being armed.
The timer for this feature is programmed in Section [370]. The value programmed in this section
determines the number of days of no-arming the system counts before sending the Delinquency
reporting code to the central station. Once this code is sent, the timer will not be started again
until the system has been armed. Each day programmed in the counter represents one day PLUS
the time it takes for the system to reach midnight. This feature may be disabled by program-
ming 000 in Section [370].
[381] - SECOND COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Opening After Alarm Keypad
Ringback
ON Opening After Alarm Keypad Ringback Enabled.
When the Opening After Alarm reporting
code is successfully transmitted to a programmed telephone number, the keypad will sound a
series of 8 beeps to confirm to the end user that the Opening After Alarm code was sent and
received. This ringback will occur for each Opening After Alarm code successfully reported.
OFF Opening After Alarm Keypad Ringback Disabled
2 Opening After Alarm Bell
Ringback
ON Opening After Alarm Bell Ringback Enabled
. When the Opening After Alarm reporting
code is successfully transmitted to a programmed telephone number, the bell will sound a series
of 8 squawks to confirm to the end user that the Opening After Alarm code was sent and
received. This ringback will occur for each Opening After Alarm code successfully transmitted.
OFF Opening After Alarm Bell Ringback Disabled
Komentarze do niniejszej Instrukcji