1.1 Specifications
Downloading Software Support
• PC5008 uses DLS-1 v6.5 and up.
Flexible Zone Configuration
• Six fully programmable zones; system expandable to eight
zones using keypad zone inputs and wireless zones
• 38 access codes: one master code, one maintenance code,
two duress codes, two supervision codes and 32 general
access codes
• 27 zone types; 8 programmable zone attributes
• Normally closed, single EOL and double EOL zone wiring
• Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
• 700mA Supervised Bell Output (current limited at 3 amps),
12VDC
• Steady or Pulsed Output
EEPROM Memory
• Does not lose programming or system status on complete AC
and Battery failure
Programmable Outputs
• One programmable voltage output and one programmable
voltage output/input; 22 programmable options
• PGM1 = 300mA; PGM2 = 50mA
• Eight additional low current (50mA) outputs available using
the PC5208 module
• Four additional high current (300mA) outputs available using
the PC5204 module; one PC5204 output fully supervised for
siren
Powerful 1.5 Amp Regulated Power Supply
• 550 mA Auxiliary Supply, 12 V
DC
• Positive Temperature Coefficient (PTC) components replace
fuses
• Supervision for loss of AC power, low battery
• Internal clock locked to AC power frequency
Power Requirements
• Transformer = 16.5 VAC, 40VA
• Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
• Two keypads available:
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
• All keypads have five programmable function keys
• Connect up to eight keypads
• 4-wire (Quad) connection to Keybus
• Built in piezoelectric buzzer
Digital Communicator Specifications
• Supports major communication formats including SIA and
Contact ID
• Event-initiated personal paging
• Three programmable telephone numbers
• Two account numbers
• Supports LINKS1000 cellular communication
• Supports LINKS2X50 Long Range Radio Transmitter
• DTMF and pulse dialing
• DPDT line seizure
• Anti-jam feature
• Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC5008 continuously monitors a number of possible trouble
conditions including:
• AC power failure
• Trouble by zone
• Tamper by zone
• Fire trouble
• Telephone line trouble
• Failure to communicate
• Low battery condition
• Bell output trouble
• Module fault (supervisory or tamper)
• Loss of internal clock
• AUX Power Supply Trouble
False Alarm Prevention Features
• Audible Exit Delay
• Audible Exit Fault
• Communication Delay
• Urgency on Entry Delay
• Quick Exit
• Cross Zone Burglary Alarm
• Rotating Keypress Buffer
Additional Features
• Auto Arm at specified time
• Keypad-activated alarm output and communicator test
• All modules connect to the system via a four wire Keybus up
to 1000’/330m from main panel
• An event buffer which records the past 128 events with both
the time and date at which they occurred; buffer can be
printed using PC5400 serial interface module, or viewed with
the LCD5500Z keypad.
• Supports the addition of the PC5132 Wireless receiver for
integration of wireless devices
• Uploading and downloading capability
• Local downloading capability through the use of the PC-LINK
adaptor
• Supports the Escort5580 Voice Prompt Module with
Automation/Lighting Control
• Supports the addition of the PC5928 Audio Interface Module
to integrate intercom stations
• Added Keybus fault protection: clock and data outputs have
been programmed to withstand shorts to +12v to prevent
control panel damage
System Introduction
S E C T I O N 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - System Introduction

11.1 SpecificationsDownloading Software Support• PC5008 uses DLS-1 v6.5 and up.Flexible Zone Configuration• Six fully programmable zones; system expan

Strona 2 - 1.3 Out of the Box

KEYPADVCOMMANDS10[✱] [3] Alarm MemoryThe Memory (or System) light will be on if any alarm occurredduring the last armed period or – in the case of 24

Strona 3 - Getting Started

KEYPADVCOMMANDS11Brightness ControlYou can select from 10 different backlighting levels. Use thearrow keys (< >) to scroll to the desired backli

Strona 4 - Accessories

KEYPADVCOMMANDS12[14] [✱] [7] [2] Reset (Command Output Option #2): Asdescribed above.[15] General Voice Prompt Help: This feature can only beprogramm

Strona 5 - 2.8 Zone Wiring

13How to ProgramSECTION4The following section of the manual describes the Installer’sProgramming function and how to program the various sections.You

Strona 6 - 2.11 LINKS Zone Wiring

HOWVTOVPROGRAM144.4 Programming Toggle Option SectionsSome programming sections contain several toggle options.The panel will use zone lights 1 throug

Strona 7 - 2.12 Keypad Zones

15Program DescriptionsThe following section explains the operation of all programmablefeatures and options and provides a summary of allcorresponding

Strona 8 - Keypad Commands

P R O G R A M D E S C R I P T I O N S16A violated Fire zone will be displayed on all keypads and canbe delayed at any keypad. Typically this zone is

Strona 9

P R O G R A M D E S C R I P T I O N S17• Transmission Delay Enable – This attribute determineswhether or not the panel will delay communicating the a

Strona 10 - ✱] to toggle

P R O G R A M D E S C R I P T I O N S18to call the central station. If the option is disabled, the panel willonly attempt to call the Third telephone

Strona 11 - 3.5 Function Keys

P R O G R A M D E S C R I P T I O N S19The restoral will not be transmitted until alldetectors indicate good battery conditions.Wireless Maintenance

Strona 12 - KEYPADVCOMMANDS

SYSTEMVINTRODUCTION21.2 Additional DevicesIn addition to the information below, see the back cover for aDSC module compatibility table.PC5132 Wireless

Strona 13 - How to Program

P R O G R A M D E S C R I P T I O N S20Additional Notes on Contact ID1. Account numbers must be four digits.2. All reporting codes must be two digits

Strona 14 - 4.5 Viewing Programming

P R O G R A M D E S C R I P T I O N S21The panel will immediately go on line and begin downloading. Ifthe Call-Back option is enabled, the panel and

Strona 15 - Program Descriptions

P R O G R A M D E S C R I P T I O N S22Program which trouble conditions will activate the output byselecting some or all of the following attributes:

Strona 16 - 5.3 Zone Attributes

P R O G R A M D E S C R I P T I O N S23[24] Audible 24 Hour (PGM2 Only)A Panic button may be placed on the PGM2 Terminal for use asan Audible 24 Hour

Strona 17 - 5.5 Communicator – Dialing

P R O G R A M D E S C R I P T I O N S24If you have selected the Land Line Test Transmis-sion in Minutes option, do not program the testtransmission c

Strona 18

P R O G R A M D E S C R I P T I O N S25Closing Confirmation ... Section [381]: [4]Opening After Alarm Keypad Ringback

Strona 19

P R O G R A M D E S C R I P T I O N S26If the Power Save Mode option is enabled the panel will blankall keypad lights including backlighting when AC

Strona 20 - 5.10 Downloading

P R O G R A M D E S C R I P T I O N S275.27 Additional System ModulesThe following modules are programmed through the ModuleProgramming sections [801

Strona 21 - 5.11 PGM Output Options

P R O G R A M D E S C R I P T I O N S283. The Fire Bell is Continuous option is disabled (section [014]:[8])4. The Transmission Delay is disabled, if

Strona 22 - ✱] [7] [2]:

29Programming WorksheetsSystem Zone Label Zone Zone Attributes* Serial NumberZone Type 1 2 3 4 5 6 7 8 (Wireless)Zone 1 I__ _ _ _

Strona 23 - 5.14 Test Transmission

3Getting StartedS E C T I O N 2The following sections provide a thorough description of how towire and configure devices and zones.2.1 Installation S

Strona 24

30P R O G R A M M I N G W O R K S H E E T SKeypad Programming[000] Keypad Enrollment (Section 2.5 “Keypad Enrollment”)NOTE: This must be done at eac

Strona 25 - 5.22 Keypad Blanking

31P R O G R A M M I N G W O R K S H E E T S[006] Installer’s Code (Section 4.1 “Installer Programming”)Default: 5008 I_______I_______I_______I______

Strona 26 - 5.25 Keypad Tampers

32P R O G R A M M I N G W O R K S H E E T S[014] Second System Option CodeDefault Option ON OFF SectionOFFI________I 1 Arm / Disarm Bell Squawk enabl

Strona 27

33P R O G R A M M I N G W O R K S H E E T S[030] Zone Loop Response OptionsDefault Option ON OFF SectionOFF I________I 1 Zone 1 is Fast Loop Response

Strona 28

34P R O G R A M M I N G W O R K S H E E T SPGM Output Attributes(Section 5.11 “PGM Output Options”)Program only the following attributes for the PGM

Strona 29 - Programming Worksheets

35P R O G R A M M I N G W O R K S H E E T S[160] Maximum Dialing Attempts to Each Telephone Number(Section 5.5 “Communicator Dialing”)Default: 008 I_

Strona 30

36P R O G R A M M I N G W O R K S H E E T S[324] Alarm Restoral Reporting Codes, Zones 1-8(Section 5.8 “Communicator – Reporting Codes” and Appendix

Strona 31

37P R O G R A M M I N G W O R K S H E E T S[341] Closing (Arming) Reporting Codes, Access Codes 17-24(Section 5.8 “Communicator – Reporting Codes” an

Strona 32 - (Section 2.12 “Keypad Zones”)

38P R O G R A M M I N G W O R K S H E E T S[349] Maintenance Alarm Reporting Codes(Section 5.8 “Communicator – Reporting Codes” and Appendix A)I_____

Strona 33

39P R O G R A M M I N G W O R K S H E E T S[363] Tamper/Restore Communicator Call Directions(Section 5.5 “Communicator – Dialing”)Default Option ON O

Strona 34

G E T T I N G S T A R T E D4Programmable Output Terminals – PGM1 andPGM2Each PGM output is designed so that when activated by thepanel, the terminal

Strona 35 - Keypad Zone Assignments

40P R O G R A M M I N G W O R K S H E E T S[371] Test Transmission Time of Day (Section 5.14 “Test Transmission”)NOTE: If the land line test transmis

Strona 36

41P R O G R A M M I N G W O R K S H E E T S[403] Downloading Access Code(Section 5.10 “Downloading”)Default: 5008 I_______I_______I_______I_______I E

Strona 37

42P R O G R A M M I N G W O R K S H E E T SModule Programming[801] PC5400 Printer Module ProgrammingPlease refer to your PC5400 Installation Manual f

Strona 38

43Reporting CodesA P P E N D I X AThe following tables contain Contact ID and Automatic SIA formatreporting codes.Contact IDThe first digit (in paren

Strona 39

44R E P O R T I N G C O D E STable 2Contact ID Zone Alarm/Restoral Event Codes(as per ADEMCO):Program any of these codes for zone alarms/restorals wh

Strona 40

45Programming LCD KeypadsA P P E N D I X BIf you have an LCD5500Z Keypad, additional programming is required for proper operation. The following is a

Strona 41

46P R O G R A M M M I N G L C D K E Y P A D S[61] Second User Display MaskDefault Option ON OFFOFFI_______I 1 Installer Programming prompt ON Instal

Strona 42 - Special Installer Functions

47ASCII Characters032064 176240033225241034035036228244038230246039231040248041249042058234043059123044060124236045061093125253046062094126238047 0630

Strona 43 - Reporting Codes

© 1998 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-7498Printed in Canada

Strona 44 - (as per ADEMCO):

• W A R N I N G •This manual contains information on limitations regarding product use and function and information on thelimitations as to liability

Strona 45 - Programming LCD Keypads

G E T T I N G S T A R T E D5calculations. Connected devices must not exceed systemcapabilities during any possible operational mode.2.5 Keypad Assign

Strona 46

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc

Strona 47 - I_______I 5-8 For Future Use

Table of ContentsiPC5008 Control Panel Wiring Diagram iiSection 1: System Introduction 11.1 Specifications ...

Strona 48 - CHANGES FOR PC5008 v2.1

PC5008 Control Panel Wiring DiagramiiTMPC5008 CONTROL PANEL WIRING DIAGRAMIncorrect connections mayresult in fuse failure or improperoperation. Inspec

Strona 49 - Installation

G E T T I N G S T A R T E D6This option should be selected if either NormallyClosed (NC) or Normally Open (NO) detectiondevices or contacts are being

Strona 50 - WARNING Please Read Carefully

G E T T I N G S T A R T E D72.12 Keypad ZonesEach “z” keypad on the system has a zone input to which adevice - such as a door contact - can be connec

Strona 51 - Table of Contents

8Keypad CommandsSECTION3Use any system keypad to enter commands and/or program thePC5008 security system. The LED keypad uses function andzone indicat

Strona 52

KEYPADVCOMMANDS9[✱] [2] Trouble DisplayThe panel constantly monitors itself for several different troubleconditions. If a trouble condition is present

Komentarze do niniejszej Instrukcji