Expandable Hybri
832
832
832
832
PC5010/5015 Main Control Panels
• PC5010 main control panel - alarm only
• PC5015 main control panel - alarm plus Downlook video capability
• support up to 32 zones using any combination of up to :
- 8 hardwire zones on main panel
- 8 hardwire zones using PC5108L video matrix module
(on PC5015 only)
- 4 general purpose hardwire zones and 2 waterflow hardwire
zones using PC5700 fire module
(in Canada only)
- 24 hardwire zones using PC5108 eight zone expander modules
- 8 keypad zones
- 32 wireless zones using PC5132 wireless receiver module
• zone programming
- all zones programmable as burglary or fire
- zone options include :
Normally Closed loop, Single End of Line
(EOL) resistor, and Double EOL resistor
(1)
(1)
keypad zones cannot be programmed as fire zones and cannot support
Double EOL resistor supervision
- 27 programmable zone types, 8 programmable zone options
• audible alarm output
- supervised bell output - 700mA @ 12VDC, PTC protected,
current limited at 3A
- steady, pulsed, temporal pattern, or strobe fire output
- additional supervised siren output is available using PC5204
power supply module
• programmable voltage outputs
- 1 high current 300mA PGM… can also be used for 2 wire smoke
with a maximum of 20 detectors at 15mA per detector
- 1 low current 50mA PGM
- 8 additional low current PGM outputs using PC5208 module
- 4 additional high current PGM outputs using PC5204 module
- 24 programmable options
• local PCLINK™ and remote upload/download capability
- program system using DLS software and direct PC connection to
control panel or via remote PC over telephone line
- view status and trouble conditions, and system 128 event buffer
- remote access can be controlled by owner to prevent
unauthorized access to system
• power supply
- 550mA @ 12.5VDC auxiliary power (400mA for UL applications)
- positive temperature coefficient (PTC) protected battery, AUX, and
Bell output
- electronic protection of KEYBUS
- supervision of AC power loss, low battery, auxiliary power failure
- internal clock locked to AC power frequency
• EEPROM memory
- will not lose programming or system status on complete AC and
battery failure
• digital communicator
- supports all major formats including SIA & Contact ID
- supports LINKS1000™ cellular communications
- supports LINKS2150™ and LINKS2450™ long range
radio communications
- 3 phone numbers (3rd backs up primary)
- 2 account numbers - DTMF or pulse dialing
- DPDT line seizure - anti-jam feature
- split reporting of selected events to each telephone number
- event initiated personal paging
• battery required : 12V, 4Ah, rechargeable sealed lead acid
• transformer required : 16.5VAC, 40VA
System Operation
• 2 system partitions… 2 account numbers
- each partition acts as a separate alarm system with any number of
zones, user codes, keypads and individually programmable
features
• 38 - 4 or 6 digit access codes
- 32 user codes, 1 system master code, 2 partition master codes,
2 duress codes, and 1 maintenance code
• automatic arming by partition
- each partition may be programmed to auto-arm at its own time
each day
• keypad lockout
- panel can be programmed to lockout keypad if a series of incorrect
access code entries are made
• ‘quick arm’ and ‘quick exit’
- allows users to arm and exit easily
• ‘stay/away’ zones and ‘stay’ arming
- security of perimeter arming while premise is occupied
• door chime
- programmable by zone
- monitor a door by having keypad beep when the door is opened
and again when door is closed
• 128 event buffer
- all events automatically stored with time and date stamp to buffer
- events can be printed on-site using the PC5400 serial printer
interface module, viewed through an LCD Keypad, or viewed and
printed via PC using DLS software
Full Supervision
The system continuously monitors the following trouble conditions :
• AC power failure • trouble by zone
• fire trouble • telephone line trouble
• low battery • bell output trouble
• loss of internal clock • tamper by zone
• fail to communicate • aux power supply fault
• module fault (supervisory or tamper)
• camera troubles
(on PC5015 with Downlook)
False Alarm Prevention Features
• audible exit delay • audible exit fault
• quick exit • urgency on entry delay
• swinger shutdown • cross zone alarm
• recent closing transmission • burglary verified timer*
• double hit timer* • communication delay
• rotating keypress buffer • arm/disarm bell squawk
* on PC5015 v2.2x and higher