Note: The Fire keys can be disabled by the installer.
LED5511/LCD5511 Keypad
Press and hold both keys simultaneously for two seconds to send the following messages:
[1][3] Fire Message
[4][6] Auxiliary Message
[7][9] Panic Message
When Alarm Sounds
The system can generate two different alarm sounds:
Continuous Siren = Intrusion (Burglary Alarm)
Temporal/Pulsed Siren = Fire Alarm
Intrusion (Burglar) Alarm Continuous Siren
If you are unsure of the source of the alarm approach with caution! If the alarm was accidental, enter your Access Code
to silence the alarm. Call your central station to avoid a dispatch.
Fire Alarm Pulsed Siren
Follow your emergency evacuation plan immediately! If the fire alarm was accidental (i.e. burned toast, bathroom
steam, etc.), enter your Access Code to silence the alarm. Call your central station to avoid a dispatch. Ask your alarm
company if your system has been equipped with fire detection. To reset the detectors, see the Sensor Reset section.
Trouble Conditions
When a trouble condition is detected, the Trouble or System indicator will turn on, and the keypad will beep every 10
seconds. Press the [#] key to silence the beeps. Press [*][2] to view the trouble condition. The Trouble or System
indicator will flash. The corresponding trouble will be represented by numbers 1-8.
LED/Digit
Trouble Condition
Comments
1
Service Required (Press [1] for
more information)
(1) Low Battery (2) Bell Circuit (3) System Trouble (4) System Tamper (5) Modulate
Supervision (6) RF Jam Detected (7) PC5204 Low Battery (8) PC5204 AC Failure
2
Loss of AC Power
If the building and/or neighborhood has lost electrical power, the system will continue to
operate on battery for several hours.
3
Telephone Line Fault
The system has detected that the telephone line is cut.
4
Failure to Communicate
The system attempted to communicate with the monitoring station, but failed. This may
be due to Trouble 3.
5
Sensor (or Zone) Fault
The system is experiencing difficulties with one or more sensors.
6
Sensor (or Zone) Tamper
The system has detected a tamper condition with one or more sensors on the system.
7
Sensor (or Zone) Low Battery
If the system has been equipped with wireless sensors, one or more has reported a low
battery condition.
8
Loss of Time & Date
If complete power was lost (AC and Battery), the time and date will need to be re-
programmed.