P R O G R A M D E S C R I P T I O N S
25
1st Phone Number .................................................. Section [301]
2nd Phone Number ................................................. Section [302]
3rd Phone Number ................................................. Section [303]
3rd Phone Number Enable ..................................... Section [380], Option [5]
Alternate Dial .......................................................... Section [380], Option [6]
5.5 Communicator - Account Numbers
There are two Partition Identifier Codes (or Account Numbers) programmable, one for each Partition. The
Account Number is used by central station to determine which panel is calling.
If the panel is programmed as two Partitions both Account Numbers must be programmed. The panel will report
to the central station by Partition. For example, if an alarm occurs on a zone assigned to Partition 1 the panel will
report using Partition 1 Account Number.
Partition 1 Identifier Code ...................................... Section [310]
Partition 2 Identifier Code ...................................... Section [311]
5.6 Communicator - Reporting Formats
Each central station phone number of the panel can be programmed to report using any one of the 5 formats
available. The following formats are supported: Pulse (10 and 20 BPS), Contact ID, SIA, Residential Dial and a
Pager format. The following is a description of each:
5.6.1 Pulse Formats
Depending on the pulse format selected the panel will communicate using the following:
3/1, 3/2, 4/1 or 4/2 1400 or 2300 Hz handshake 10 or 20 bits per second non-extended
Additional Notes on Pulse Formats
1. The digit 0 will send no pulses and is used as a filler.
2. When programming account numbers enter four digits.
3. When programming a three digit account number the fourth digit must be programmed as a plain 0 which will
act as a filler digit.
4. If an account number has a 0 in it, substitute a HEX digit A for the 0. Examples:
3 digit account number [123] - program [1230] 3 digit account number [502] - program [5A20]
4 digit account number [4079] - program [4A79]
5. When programming reporting codes two digits must be entered. If one digit reporting codes are to be used
the second digit must be programmed as a 0. If a 0 is to be transmitted substitute a HEX digit A for the 0.
Examples:
1 digit reporting code [3] - program [30] 2 digit reporting code [30] - program [3A]
6. To prevent the panel from reporting an event program the reporting code for the event as [00] or [FF].
This communication forThis communication for
This communication forThis communication for
This communication for
mat cannot be selected if Downlook is rmat cannot be selected if Downlook is r
mat cannot be selected if Downlook is rmat cannot be selected if Downlook is r
mat cannot be selected if Downlook is r
equirequir
equirequir
equir
ed.ed.
ed.ed.
ed.
Communicator Format Options .............................. Section [360]
5.6.2 Contact ID
Contact ID is a specialized format that will communicate information using tones rather than pulses. This format
allows more information to be sent faster than other formats. For example, in addition to reporting an alarm in
zone one, the Contact ID format will also report the type of alarm, such as an Entry/Exit alarm.
If the
Contact ID uses Programmed Reporting CodesContact ID uses Programmed Reporting Codes
Contact ID uses Programmed Reporting CodesContact ID uses Programmed Reporting Codes
Contact ID uses Programmed Reporting Codes option is enabled, a two digit number from Appendix A
must be entered in programming sections [320] to [353] for each event to be transmitted. The two digit number
determines the type of alarm. The panel will automatically generate all other information, including the zone
number.
If the
Contact ID uses Automatic Reporting CodesContact ID uses Automatic Reporting Codes
Contact ID uses Automatic Reporting CodesContact ID uses Automatic Reporting Codes
Contact ID uses Automatic Reporting Codes option is enabled, the panel will operate as follows:
1. If an events reporting code is programmed as [00], the panel will not attempt to call the central station.
2. If the reporting code for an event is programmed as anything from [01] to [FF], the panel will automatically
generate the zone or access code number. See Appendix A for a list of the codes which will be transmitted.
If the Automatic Contact ID option is selected, the panel will automatically generate all zone andIf the Automatic Contact ID option is selected, the panel will automatically generate all zone and
If the Automatic Contact ID option is selected, the panel will automatically generate all zone andIf the Automatic Contact ID option is selected, the panel will automatically generate all zone and
If the Automatic Contact ID option is selected, the panel will automatically generate all zone and
access code numbers, eliminating the need to praccess code numbers, eliminating the need to pr
access code numbers, eliminating the need to praccess code numbers, eliminating the need to pr
access code numbers, eliminating the need to pr
ogram these items.ogram these items.
ogram these items.ogram these items.
ogram these items.
If the
Contact ID uses Programmed Reporting CodesContact ID uses Programmed Reporting Codes
Contact ID uses Programmed Reporting CodesContact ID uses Programmed Reporting Codes
Contact ID uses Programmed Reporting Codes option is enabled, the panel will operate as follows:
1. If an events reporting code is programmed as [00] or [FF], the panel will not attempt to call central station.
2. If the reporting code for an event is programmed as anything from [01] to [FE], the panel will send the
programmed reporting code.
Additional Notes on Contact ID
1. Account numbers must be four digits.
2. All reporting codes must be two digits.
3. Substitute the HEX digit A for the 0.
4. To prevent the panel from reporting an event, the reporting code should be programmed as [00].