The following sections provide a complete description of how to wire and configure devices and zones.
2.1 Installation Steps
The following steps are provided to assist with the installation of the panel. It is suggested that you read over this
section briefly to get an overall understanding of the order of installation. Once this is done carefully work
through each step. Working from this plan will help reduce problems and reduce the overall installation time
required.
Step 1 Create a Layout
Draw a rough sketch of the building and include all alarm detection devices, zone expanders, keypads and all
other modules that are required.
Step 2 Mounting the Panel
Locate the panel in a dry area, preferably located near an unswitched AC power source and the incoming
telephone line. Before attaching the cabinet to the wall be sure to press the five circuit board mounting
studs into the cabinet from the back.
Complete all wiring beforComplete all wiring befor
Complete all wiring beforComplete all wiring befor
Complete all wiring befor
e applying AC or connecting the battere applying AC or connecting the batter
e applying AC or connecting the battere applying AC or connecting the batter
e applying AC or connecting the batter
yy
yy
y
..
..
.
Step 3 Wiring the Keybus
(Section 2.3)
Wire the Keybus to each of the modules following the guidelines provided.
Step 4 Assigning Zones to Zone Expanders
(Section 2.5)
If zone expander modules are being used the modules must be configured so the panel knows which zones are
assigned to each expander. Follow the guideline provided to assign zones to expanders.
Step 5 Zone Wiring
(Section 2.9)
Power down the control panel and complete all zone wiring. Follow the guidelines provided in Section 2.9 to
connect zones using normally closed loops, single EOL resistor, double EOL resistors, Fire zones and Keyswitch
Arming zones.
Step 6 Completing Wiring
Complete all other wiring including bells or sirens, phone line connections, ground connections or any other
wiring necessary. Follow the guidelines provided in Section 2.2 “Terminal Descriptions”.
Step 7 Power up the Control Panel
Once all zone wiring and Keybus wiring is complete, power up the control panel.
The panel will not power up if only the batterThe panel will not power up if only the batter
The panel will not power up if only the batterThe panel will not power up if only the batter
The panel will not power up if only the batter
y is connected.y is connected.
y is connected.y is connected.
y is connected.
Step 8 Keypad Assignment
(Section 2.6)
Keypads must be assigned to different addresses to be properly supervised. Follow the guideline provided in
Section 2.6 to assign keypads.
Step 9 Enabling Supervision
(Section 2.7)
After all modules have been wired to the Keybus, supervision must be enabled. Once supervision is enabled, the
panel will be able to indicate module communication faults. Follow the guidelines provided in Section 2.7.
Step 10 Programming the System
(Sections 4 and 5)
Section 4.0 provides a complete description of how to program the panel. Section 5.0 contains complete
descriptions of the various programmable features, what options are available and how the options function. The
Programming Work Sheets should be filled out completely before attempting to program the system.
Step 11 Testing the System
Test the panel completely to ensure that all features and functions are operating as programmed.
2.2 Terminal Descriptions
AC Terminals - AC
The panel requires a 16.5 volt, 40 VA transformer. Connect the transformer to an unswitched AC source and
connect the transformer to these terminals.
Do not connect the transforDo not connect the transfor
Do not connect the transforDo not connect the transfor
Do not connect the transfor
mer until all other wiring is completemer until all other wiring is complete
mer until all other wiring is completemer until all other wiring is complete
mer until all other wiring is complete
..
..
.
Battery Connection
The battery is used to provide back up power in the event of an AC power failure and to provide additional current when
the panel demands exceed the power output of the transformer, such as when the panel is in alarm.
Do not connect the batterDo not connect the batter
Do not connect the batterDo not connect the batter
Do not connect the batter
y until all other wiring is completey until all other wiring is complete
y until all other wiring is completey until all other wiring is complete
y until all other wiring is complete
.
Connect the RED battery lead to the positive of the battery, the BLACK battery lead to the negative.