P R O G R A M D E S C R I P T I O N S
36
5.23 Keypad Blanking
If the Keypad Blanking Option
is enabled the panel will turn off all lights and LCDs on the keypads if no key is
pressed for 30 seconds. The keys, however, will remain backlit.
The panel will turn the lights and LCDs back on if entry delay begins or an audible alarm occurs. The lights and
LCDs will also come on if a key is pressed or, if the Code Required to Restore Blanking Option
is enabled, a
valid access code is entered.
If the Power Save Option
is enabled the panel will blank all keypad lights including backlighting when AC
power fails, in order to conserve the back up battery.
Keypad Blanking Option ......................................... Section [016], Option [3]
Code Required to Restore Blanking ...................... Section [016], Option [4]
Power Save Option ................................................. Section [016], Option [6]
5.24 Loop Response
The normal loop response time for all zones is 500 milliseconds. The panel will not consider a zone violated
unless it is violated for at least 500 milliseconds.
If Zone 1 is Fast Loop Response is enabled the loop response for zone 1 will be 40 milliseconds. Typically this
can be used for vibration type sensors.
Zone 1 is Fast Loop Response .............................. Section [013], Option [5]
5.25 Keypad Tampers
If the Keypad Tampers Enable option is selected the panel will display and transmit a General System Tamper
reporting code if any keypad is removed from the wall. When the keypad tamper is restored the panel will
transmit the General System Tamper Restoral reporting code. All keypads should be properly installed and
secured before enabling this option.
By enabling Tampers/Faults Do Not Show as Open, faults and tampers for keypad zones will not show as
open on the keypad, and will be hidden from the end user. If the option is disabled, faults and tampers will show
as open.
Entering and exiting InstallerEntering and exiting Installer
Entering and exiting InstallerEntering and exiting Installer
Entering and exiting Installer
s Prs Pr
s Prs Pr
s Pr
ogramming will not rogramming will not r
ogramming will not rogramming will not r
ogramming will not r
eset the system tampers. All tamper conditionseset the system tampers. All tamper conditions
eset the system tampers. All tamper conditionseset the system tampers. All tamper conditions
eset the system tampers. All tamper conditions
must also be physically rmust also be physically r
must also be physically rmust also be physically r
must also be physically r
estorestor
estorestor
estor
ed.ed.
ed.ed.
ed.
Once a zone is tamperOnce a zone is tamper
Once a zone is tamperOnce a zone is tamper
Once a zone is tamper
ed or faulted, it must be completely red or faulted, it must be completely r
ed or faulted, it must be completely red or faulted, it must be completely r
ed or faulted, it must be completely r
estorestor
estorestor
estor
ed befored befor
ed befored befor
ed befor
e the tre the tr
e the tre the tr
e the tr
ouble condition will clearouble condition will clear
ouble condition will clearouble condition will clear
ouble condition will clear
..
..
.
Keypad Tamper Enable......................................................... Section [016], Option [8]
General System Tamper Reporting Code ............................ Section [338]
General System Tamper Restoral Reporting Code ............. Section [338]
Tamper/Fault Do Not Show As Open ................................... Section [013], Option [4]
5.26 LINKS1000 Cellular Communicator
The LINKS1000 cellular communicator can be used three different ways: as the sole communicator for the panel, as a
back up for either or both phone numbers or as a redundant back up to the land line communicator (the panel will call
both the land line and via the LINKS). A LINKS Preamble is programmable for each phone number in the event that the
land line number is local but the LINKS is required to dial an exchange. When programming a LINKS Preamble, all
unused digits must be programmed with a hex decimal F.
5.26.1 Sole Communicator
The panel can be programmed to report only using the LINKS1000 cellular communicator when an event
occurs. To program this select only the LINKS1000 for the Communicator Call Direction Options for the event.
In addition the Call LINKS as well as Land Line option must also be enabled.
When the selected event occurs the panel will only attempt to call central station using the LINKS.
5.26.2 Backup Communicator
The panel can be programmed to call using the LINKS1000 cellular communicator if the panel is having difficulty
communicating an event using the land line. To program this select both the phone number and LINKS options
for the Communicator Call Direction Options for the event. In addition the LINKS is Backup of Land Lines option
must be selected.
When used as a backup communicator the panel will attempt to call the central station in the following manner:
the panel will try to call using land lines - if unsuccessful the panel will try to call using the LINKS
if unsuccessful the panel will try to call using the land lines
if unsuccessful the panel will try to call using the LINKS
This process will continue until the panel has successfully communicated with the central station or the
Maximum Dialing Attempts has been reached.
5.26.3 Redundant Communicator
The panel can be programmed to call using both the land line and the LINKS1000 cellular communicator when an event
occurs. To program this select both the phone number and the LINKS options for the Communicator Call Direction
Options for the event. In addition the Call LINKS as well as Land Line option must be selected.
The panel will call the LINKS and then call the land line when reporting the selected event.