DSC Power832 Security System PC5016 Dokumentacja Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 28
P R O G R A M D E S C R I P T I O N S
29
5.10 PGM Outputs
There are 3 different types of Programmable Outputs available. They are listed as follows:
• PGM1 and PGM2 on the main board
• 8 low current outputs available with the PC5208 Output Module
• 4 high current outputs available with the PC5204 Power Supply/Output Module
Programming any of the PGM Outputs is a two step process. First an option from the below list must be
selected for the PGM Output. Second the PGM Attributes must be selected. The following is a list of the
PGM Output Options and PGM Attributes.
5.10.1 PGM Output Options
[01] Burglary and Fire Bell Output
The PGM output will activate when the alarm output is active and will turn off when the alarm output is
silenced. If the alarm output is pulsing the PGM output will pulse as well. This output does not follow the
pre-alert for delayed fire zones.
[02] Utility Output
The PGM output will activate for 5 seconds when the [
][7][1][Access Code] command is entered
(See
Section 3.0 “Keypad Commands”).
[03] Sensor Reset
This option is used to reset power for latching smoke detectors.
The output will normally be active, switched to ground.
The output will deactivate for 5 seconds when the [ ][7][2] command is entered
(See Section 3.0
“Keypad Commands”)
. The keypad buzzer will not sound for the 5 second period.
Refer to the hookup diagram in this manual for wiring instructions.
[04] For Future Use
[05] Partition/System Armed Status
The PGM output will activate when the Partition or System is armed and deactivate when disarmed.
[06] Ready Output
The PGM output will activate when the Partition or System is ready to arm. The output will deactivate when
the system is not secure or upon arming.
[07] Keypad Buzzer Follow
The PGM will activate when any of the following events occur and will remain active for as long as the
keypad buzzer is active:
• Doorchime • Entry Delay • Audible Exit Delay
• Auto-Arm Prealert • 24 Hour Supervisory Buzzer Zone
[08] Courtesy Pulse
Upon arming the PGM output will activate for the duration of the exit delay plus two minutes. Upon entry
the PGM output will activate for the duration of the entry delay plus two minutes. Only one courtesy pulse
output may be programmed on a system.
[09] System Trouble
The PGM output will activate when any of the selected trouble conditions are present. It will deactivate
when all the selected trouble conditions are cleared.
The normal PGM attributes, programmed in Sections [141] to [154] is replaced with the following list for
any output selected as System Trouble:
Light [1] Service Required (battery, bell, general trouble, general tamper, general supervisory)
Light [2] AC Failure
Light [3] Telephone Line Trouble
Light [4] Failure to Communicate
Light [5] Fire Trouble / Zone Fault
Light [6] Zone Tamper
Light [7] Zone Low Battery
Light [8] Loss of Clock