P R O G R A M D E S C R I P T I O N S
30
[10] Latched System Event
The PGM output will activate when any of the selected events occur. It will deactivate when an access
code is entered. Global alarms must be silenced with a global code.
The normal PGM attributes, programmed in Sections [141] to [154] is replaced with the following list for
any output selected as Latched System Event:
Light [1] Burglary......... Delay, Instant, Interior, Stay/Away and 24 Hour Burglary Zones
Light [2] Fire ................ Fire Keys, Fire Zone (PGM Output)
Light [3] Holdup .......... Holdup zones and Duress alarms
Light [4] Medical ......... Auxiliary Keys, Medical and Emergency Zones
Light [5] Supervisory ... Supervisory, Freezer and Water Zones
Light [6] Priority ........... Gas, Heat, Sprinkler and 24 Hour Latching Zones
Light [7] Partition 1 PGM enable ]
Either or both of these lights should be ON to indicate
Light [8] Partition 2 PGM enable ]
which Partition(s) will activate the PGM output.
[11] System Tamper
The PGM Output will activate when any Tamper condition is present and will deactivate when all Tamper
conditions are cleared.
[12] TLM and Alarm
The PGM Output will activate when a telephone line fault condition is present AND an alarm occurs. The
PGM Output will remain active until an access code is entered. The output will activate for both audible
and silent alarms if a TLM trouble is present.
This output will activate for all audible and silent alarms except Duress.
[13] Kissoff
The PGM Output will activate for two seconds after the panel receives the kissoff from the central station.
[14] Ground Start
The PGM Output will activate for two seconds before the panel attempts to dial to obtain dial tone on
Ground Start telephone equipment. Two 2-second pauses should be inserted at the beginning of the
phone number when using this option.
Main Board PGM Outputs ............................. Section [009]
PC5208 PGM Output Options ....................... Section [010]
PC5204 PGM Output Options ....................... Section [011]
5.10.2 PGM Output Attributes
Each Programmable Output also requires the PGM Attributes to be programmed before they will operate
correctly. Attributes available are as follows:
PGM Options 2, 3, 5-7 PGM Options 1, 8, 11-16
Option [1] - ON Partition 1 Controls Event Option [1] - Must be ON
OFF Partition 1 Does Not Option [3] - ON Output Activates on Event
Option [2] - ON Partition 2 Controls Event OFF Output Deactivates on Event
OFF Partition 2 Does Not
Option [3] - ON Output Activates on Event
OFF Output Deactivates on Event
The Attribute Options for Option [09] System Trouble and [10] Latched System Event are
different. Refer to these options for more information.
PGM1 (Main Board) Output Attributes .......... Section [141]
PGM2 (Main Board) Output Attributes .......... Section [142]
PC5208 PGM Output Attributes .................... Section [143] to [150]
PC5204 PGM Output Attributes .................... Section [151] to [154]
5.11 Telephone Line Monitor (TLM)
The panel will supervise the presence of the phone line and indicate a trouble condition if disconnected. If
TLM Enabled
is selected the panel will wait the TLM Trouble Delay
time before indicating the trouble so
that a momentary interruption of the phone line will not cause a trouble condition.
The TLM Trouble Only
or Audible When Armed
option will allow you to select if the panel will indicate a
trouble condition at the keypad or indicate a trouble at the keypad when disarmed and activate the alarm
output when armed.