KEYPAD SETUP
[✱]+[6]+[ACCESS CODE]+[3]
This function allows the user to adjust the backlighting and contrast of the LCD-4500
keypad. When this function is selected, the Keypad Setup menu will appear on the
keypad.
■
Bright Control adjusts the level of back lighting on the LCD display and the
backlighting on the keys.
■
Contrast Control adjusts the contrast of the lettering on the LCD display.
Use the [<][>] keys to toggle through the eight different settings, and press [✱] to
select the level of preference.
BELL/COMM TEST
[✱]+[6]+[ACCESS CODE]+[4]
This option allows the end user to test the system. This option activates the bell’s for
two seconds and sends a test code transmission to the monitoring station.
DOOR CHIME
[✱]+[6]+[ACCESS CODE]+[5]
The Door Chime feature is enabled or disabled by pressing the [✱] key to toggle from
“N” to “Y” or “Y” to “N”. When the chime zone is activated, the keypad will beep
quickly 5 times. The “Beeping” on doors can be eliminated temporarily by using zone
bypass, only when the panel is disarmed.
SPEC. MESSAGES
[✱]+[6]+[ACCESS CODE]+[6]
This function enables two special event messages to be displayed when one of the
special events occurs.
The first message is “Fail to Arm”. It will be displayed if the user is unable to arm the
partition after entering a valid code (E.g. Because of activity on the zones.).
The second message is “Alarm When Armed”. It will be displayed if an alarm
occurred during the previous armed period.
USER CALL UP
[✱]+[6]+[ACCESS CODE]+[7]
This function must be enabled by the installer. When selected, the panel will call the
downloading computer. The downloading computer must be waiting for the panel to
call before downloading can be performed.
TROUBLE DISPLAY
[✱]+[2]
The PC4000 continuously monitors a number of possible trouble conditions. If one of
these conditions occurs, the keypad “TROUBLE” indicator will light and the audible
indication will sound (two short beeps every 10 seconds). When the [#] key is
pressed the audible indication will stop on that partition, but the trouble indicator light
will remain ON until the trouble is cleared. Trouble conditions can also be transmitted
to the monitoring station. Press the [✱] then [2] keys to display the trouble conditions.
■
Low stand-by battery
■
Loss of time on internal clock
■
AC power failure
■
COMBUS communications fault
■
Auxiliary supply trouble
■
COMBUS low voltage
■
Telephone line trouble
■
Internal fault
■
Bell circuit failure
■
4204 Battery TBL
■
Smoke detector loop trouble
■
4204 AC Trouble
■
Unsuccessful communication
■
4204 Aux Trouble
attempt with monitoring station
Press [#] to return to “READY”.
Low Battery...A battery trouble will be displayed if the battery is low, disconnected
or the battery fuse fails.
AC Power Failure...There is no audible annunciation on AC power failure. The
system “Trouble” light will come ON but the audible indication will not sound until
there is a low battery condition.
Auxiliary Supply Trouble...A trouble is generated if the auxiliary fuse fails.
Telephone Line Trouble...A telephone line trouble is generated when the line voltage
drops below 3 volts for more than 30 seconds. A keypad trouble is generated when the
system is disarmed and if selected, a local alarm sounds when the panel is armed.
Unsuccessful Communication...If the digital communicator is unsuccessful in
communicating with the monitoring station after 10 attempts, a Fail to Communicate
trouble is generated. If a later attempt to communicate is successful the trouble is
cleared.
Bell Circuit Failure...If the bell fuse opens or the bell circuit is open, a keypad
trouble and a Bell Circuit trouble transmission are generated.
Smoke Detector Loop Trouble...If a FIRE loop is open circuit, a keypad trouble
and a Fire Loop trouble transmission are generated. A trouble on the FIRE loop will
unconditionally initiate an audible indication on the keypad. This means that even if
any other previous trouble has been silenced, a FIRE loop trouble will restart the
keypad buzzer.
Loss of Internal Time...When the PC4000 is powered up, the internal time of day
clock needs to be set to the correct time. Programming the time will clear this trouble.
COMBUS Communications Fault...Contact installer.
COMBUS Low Voltage...Contact installer.
Internal Fault...Contact installer.
4204 Battery TBL...If any PC4204 relay output module’s battery drops below 11.3
volts, a battery trouble is generated.
The battery voltage is checked once every 4 minutes. So the battery trouble may not
restore instantly when the battery voltage is restored.
4204 AC Trouble...If any PC4204 relay output module loses incoming AC power,
the keypad trouble light will indicate a 4204 AC trouble. But there will be no audible
annunciation until there is also a low battery condition.
4204 AUX Trouble...If the Aux fuse on any PC4204 relay module should open or if
the Aux supply is overloaded, a 4204 Aux trouble is generated.