P R O G R A M D E S C R I P T I O N S
27
5.7.4 Openings
The panel will transmit an Opening Reporting Code to indicate a Partition(s) has been disarmed. A different
reporting code can be transmitted for each User Code, Partition Master Code and System Master Code to
identify who disarmed the Partition(s).
A Special Opening Reporting Code will be transmitted if the Partition(s) is disarmed using any of the following methods:
Disarming using the Maintenance Code Disarming via the DLS Software Disarming via keyswitch
An Opening After Alarm Reporting Code will be transmitted in addition to the opening when the Partition(s) is
disarmed after an alarm has occurred.
An Opening by Duress Reporting Code will be transmitted in addition to the Duress reporting code if a
Partition(s) is disarmed using a Duress Code.
5.7.5 Tampers
If the panel is programmed for Double EOL zones
(See Section 2.9 Zone Wiring)
the panel will report a Zone
Tamper Alarm Reporting Code if an open condition is present on a zone. A different reporting code can be
programmed for each zone for identification. The Zone Tamper Restoral Reporting Code will be transmitted
immediately when the tamper condition is restored.
A General System Tamper Reporting Code will be transmitted when the tamper zone on any module is violated.
The General System Tamper Restoral Reporting Code will be transmitted when the tamper zone on the module
is restored.
5.7.6 Priority/Emergency
The panel will transmit a Keypad Fire Alarm Reporting Code AND the Keypad Fire Restoral Reporting Code
when the Fire Keys on any keypad is pressed for two seconds.
The panel will transmit a Keypad Auxiliary Alarm Reporting Code AND the Keypad Auxiliary Restoral
Reporting Code when the Auxiliary Keys on any keypad is pressed for two seconds.
The panel will transmit a Keypad Panic Alarm Reporting Code AND the Keypad Panic Restoral Reporting
Code when the Panic Keys on any keypad is pressed for two seconds.
The panel will transmit a Duress Reporting Code any time either Duress Code is entered at any keypad. If the
panel is armed using the Duress Code the panel will also transmit a Closing by Duress Reporting Code or if the
panel is disarmed it will also transmit an Opening by Duress Reporting Code.
If PGM2 is being used for two wire smoke detectors
(See Section 5.10 PGM Outputs)
the panel will send a
PGM2 Alarm Reporting Code if a smoke detector goes into alarm. The panel will transmit the PGM2 Alarm
Reporting Code when the zone is restored.
If you use the SIA automatic reporting format, the panel will send “Two Wire Smoke Alarm/Restoral”
reporting code.
5.7.7 Maintenance
The panel will transmit a Battery Trouble Alarm Reporting Code when the backup battery drops below 11.5
V
DC. The Battery Trouble Restoral Reporting Code will not be transmitted until the battery has been charged
over 12.5 V
DC.
To prevent the panel from transmitting an AC Failure Trouble Alarm Reporting Code during short power
outages the panel will not send the signal unless AC power is lost for the amount of minutes programmed for the
AC Failure Communication Delay. The AC Failure Trouble Restoral Reporting Code will be transmitted once
AC power has been restored for the amount of time programmed for AC Failure. Communication delays.
NOTES: If AC Failure Communications Delay is programmed as 000, the AC Failure Trouble reporting
code will be sent immediately.
For proper communication of PC5204 AC troubles, program the AC Failure Communictaion Delay as “000”.
A Bell Circuit Trouble Alarm Reporting Code will be transmitted immediately if an open condition is measured
on the Bell Output of the main panel. The Bell Circuit Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
A Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on any
Fire type zone
(See Section 5.1 Zone Definitions).
The Fire Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is shorted.
The AUX output control incorporates a fuseless design. When excessive current is drawn the panel will
automatically shut off the output. The panel will constantly check the AUX output and when the excessive
current draw is removed the panel will reset the output and transmit an Auxiliary Power Supply Trouble
Restoral Reporting Code.
A TLM Trouble Reporting Code can only be transmitted if a LINKS1000/2X50 Communicator is being used
(See
Section 5.26 LINKS1000 Cellular Communicator)
. The panel will only transmit the signal after the time
programmed for the TLM Trouble Delay. The TLM Restoral Reporting Code will be transmitted immediately
once the trouble is restored.
A General System Trouble Reporting Code will be transmitted if the panel detects any of the following on the
PC5204 Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1
Supervisory trouble. The General System Trouble Restoral Reporting Code will be transmitted when all of the