P R O G R A M D E S C R I P T I O N S
28
A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from the
Keybus. If the module is a zone expander the panel will also transmit the Zone Expander Supervisory Alarm
Trouble Reporting Code. The panel will send a General System Supervisory Restoral Reporting Code when the
problem is corrected as well as a Zone Expander Supervisory Restoral Reporting Code if the module is a zone
expander.
5.7.8 Test Transmissions
The panel can be programmed to transmit a Periodic Test Transmission
Reporting Code
(See Section 5.13 “Test
Transmissions”)
, a System Test Reporting Code
(See Section 3.4 “[
✱
] Commands, [
✱
] [6]”)
or a LINKS1000 Test
Transmission Reporting Code
(See Section 5.26 “LINKS1000 Cellular Communicator”).
5.7.9 Wireless Maintenance
The panel will transmit a General Zone Low Battery Alarm Reporting Code if a low battery condition is indicated
by a detector. The transmission of the trouble will be delayed by the number of days programmed for Zone Low
Battery Transmission Delay. The General Zone Low Battery Restoral Reporting Code will be transmitted when
the problem is corrected. The specific zone that caused the trouble will be stored to the Event Buffer.
The restoral will not be transmitted until all detectors indicate a good battery condition.
5.7.10 Miscellaneous
The panel will transmit the Keypad Lockout Reporting Code if the lockout is activated
(See Section 5.22
“Keypad Lockout”)
.
The DLS Lead In Reporting Code will only be transmitted if the DLS Call Back feature is being used
(See Section
5.8 “Downloading”)
. Before the panel calls the computer back it will call central station and transmit the reporting
code to indicate a download session is about to begin. After downloading is complete the panel will transmit a DLS
Lead Out Reporting Code to indicate the download session is complete.
If the panel fails to transmit information to the central station it will display a failure to communicate trouble
condition. The panel will transmit a Phone Number 1 Failure to Communicate Reporting Code or a Phone
Number 2 Failure to Communicate Reporting Code the next time it calls the central station. The panel will
transmit the old events, followed by the failure to communicate, followed by the new events. This will allow
central station to determine which events are old or new.
If the Event Buffer is uploaded on a regular basis an Event Buffer 75% Full Reporting Code can be transmitted
to warn the Buffer is almost full. This is also useful if the PC5400 Printer Module is being used.
The Delinquency reporting code is sent whenever the panel is not armed within the number of days
programmed for the Delinquency Transmission Delay.
If the Delinquency Transmission Delay is set for one day, there must be 24 hours of no arming or
disarming before the Delinquency Code will be sent.
After a Delinquency Code has been transmitted, it will not send again until the system has been
armed and disarmed.
5.7.11 Activity Delinquency
When Delinquency Follows Zone Activity is enabled, if there is no activity on zones in the system, the
Delinquency Transmission Cycle Timer in Section [370] will begin counting in hours. When the counter reaches
the programmed time, the panel will communicate the Delinquency reporting code to the central station, if
programmed. If there is zone activity present on the system at any time, the counter will be reset. If this option
is used, the Delinquency Follows Arming option is not available.
Activity Delinquency will not be reported while the panel is armed in Away mode.
Activity on bypassed zones will not reset the timer. PGM2 activation will not reset the timer.
This timer is reset when the panel is armed, or if Installer Programming is entered.
When using the SIA FSK communication format with Activity Delinquency, the Closing Delinquency
identifier is transmitted.
Reporting Codes .................................................... Sections [320] to [353]
Delinquency Follows Zone Activity ......................... Section [380], Option [8]
Delinquency Transmission Cycle .......................... Section [370]
5.8 Downloading
Downloading allows programming of the entire control panel via a computer, modem and telephone line. All
functions and features, changes and status, such as trouble conditions and open zones can be viewed or
programmed by downloading.
When power is applied to the panel, a 6 hour or 1 hour downloading window can be enabled. This will
allow you to perform downloading without having to do any keypad programming.
If the Answering Machine Override
option is enabled (or during the first 6 hours after power up) the panel
will answer incoming calls for downloading provided the following conditions occur:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the Answering Machine Double Call Timer
expires it will answer on
the first ring of the second call.